Penentuan Nilai Arus Pemutusan Pemutus Tenaga Sisi 20 KV pada Gardu Induk 30 MVA Pangururan

Main Authors: Yusmartato, Yusmartato, Ramayulis, Ramayulis, Hasibuan, Abdurrozzaq
Format: Article info application/pdf Journal
Bahasa: eng
Terbitan: JET (Journal of Electrical Technology) , 2018
Online Access: https://jurnal.uisu.ac.id/index.php/jet/article/view/296
https://jurnal.uisu.ac.id/index.php/jet/article/view/296/321
ctrlnum --jurnal.uisu.ac.id-index.php-index-oai:article-296
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Penentuan Nilai Arus Pemutusan Pemutus Tenaga Sisi 20 KV pada Gardu Induk 30 MVA Pangururan</title><creator>Yusmartato, Yusmartato</creator><creator>Ramayulis, Ramayulis</creator><creator>Hasibuan, Abdurrozzaq</creator><description lang="en-US">Jaringan distribusi 20 kV berfungsi menyalurkan energi listrik dari gardu induk ke konsumen. Pasa jaringan udara 20 kV sering terjadi gangguan terutama gangguan hubung singkat. Maka pada jaringan distribusi dipasang sistem pengaman. Dalam setiap sistem pengaman listrik minimum terdiri dari pemutus tenaga, relay, &#xA0;dan transformator ukur. &#xA0;Pemutus Tenaga (PMT) atau Circuit Breaker (CB) merupakan saklar mekanis, yang mampu menutup, mengalirkan dan memutus arus beban dalam kondisi normal serta mampu menutup, mengalirkan dan memutus arus beban dalam kondisi gangguan seperti kondisi hubung singkat. Salah satu alat pengaman &#xA0;jaringan distribusi adalah Pemutus Tenaga. Dalam keadaan gangguan, pemutus tenaga harus mampu melokalisir titik gangguan sehingga tidak merusak peralatan listrik yang lain. Dalam hal ini untuk penentuan nilai arus pemutusan kapasitas pemutus tenaga, arus gangguan yang dihitung adalah gangguan hubung singkat tiga phasa, hal ini dilakukan karena arus gangguan tersebut merupakan nilai arus yang terbesar. Salah satu faktor yang menyebabkan besar arus gangguan hubung singkat tiga adalah letak titik gangguan. sehingga titik gangguan diasumsikan titik ganguannya berada di ujung penyulang/saluran, di busbar dan di dalam transformator. Setelah dilakukan perhitungan, nilai arus pemutusan pemutus tenaga untuk penyulang adalah 7,76 kA, untuk arus pemutusan pemutus tenaga &#xA0;Busbar 20 kV adalah 9,33 kA dan untuk Transformator adalah 68,44 kA.</description><publisher lang="en-US">JET (Journal of Electrical Technology)</publisher><contributor lang="en-US"/><date>2018-02-15</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Journal:Article</type><type>File:application/pdf</type><identifier>https://jurnal.uisu.ac.id/index.php/jet/article/view/296</identifier><source lang="en-US">JET (Journal of Electrical Technology); Vol 3, No 1 (2018): JET (Journal of Electrical Technology) Edisi Februari; 53-58</source><language>eng</language><relation>https://jurnal.uisu.ac.id/index.php/jet/article/view/296/321</relation><rights lang="en-US">Copyright (c) 2018 JET (Journal of Electrical Technology)</rights><recordID>--jurnal.uisu.ac.id-index.php-index-oai:article-296</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
File:application/pdf
File
Journal:Journal
author Yusmartato, Yusmartato
Ramayulis, Ramayulis
Hasibuan, Abdurrozzaq
title Penentuan Nilai Arus Pemutusan Pemutus Tenaga Sisi 20 KV pada Gardu Induk 30 MVA Pangururan
publisher JET (Journal of Electrical Technology)
publishDate 2018
url https://jurnal.uisu.ac.id/index.php/jet/article/view/296
https://jurnal.uisu.ac.id/index.php/jet/article/view/296/321
contents Jaringan distribusi 20 kV berfungsi menyalurkan energi listrik dari gardu induk ke konsumen. Pasa jaringan udara 20 kV sering terjadi gangguan terutama gangguan hubung singkat. Maka pada jaringan distribusi dipasang sistem pengaman. Dalam setiap sistem pengaman listrik minimum terdiri dari pemutus tenaga, relay, dan transformator ukur. Pemutus Tenaga (PMT) atau Circuit Breaker (CB) merupakan saklar mekanis, yang mampu menutup, mengalirkan dan memutus arus beban dalam kondisi normal serta mampu menutup, mengalirkan dan memutus arus beban dalam kondisi gangguan seperti kondisi hubung singkat. Salah satu alat pengaman jaringan distribusi adalah Pemutus Tenaga. Dalam keadaan gangguan, pemutus tenaga harus mampu melokalisir titik gangguan sehingga tidak merusak peralatan listrik yang lain. Dalam hal ini untuk penentuan nilai arus pemutusan kapasitas pemutus tenaga, arus gangguan yang dihitung adalah gangguan hubung singkat tiga phasa, hal ini dilakukan karena arus gangguan tersebut merupakan nilai arus yang terbesar. Salah satu faktor yang menyebabkan besar arus gangguan hubung singkat tiga adalah letak titik gangguan. sehingga titik gangguan diasumsikan titik ganguannya berada di ujung penyulang/saluran, di busbar dan di dalam transformator. Setelah dilakukan perhitungan, nilai arus pemutusan pemutus tenaga untuk penyulang adalah 7,76 kA, untuk arus pemutusan pemutus tenaga Busbar 20 kV adalah 9,33 kA dan untuk Transformator adalah 68,44 kA.
id IOS5113.--jurnal.uisu.ac.id-index.php-index-oai:article-296
institution Universitas Islam Sumatera Utara
institution_id 1254
institution_type library:university
library
library Universitas Islam Sumatera Utara
library_id 1095
collection JET (Journal of Electrical Technology)
repository_id 5113
subject_area Electronics/Teknik Elektronika
Data Processing, Computer Science/Pemrosesan Data, Ilmu Komputer, Teknik Informatika
Communications Telemunications/Komunikasi Telekomunikasi
Radiowave and Microwave Electronics/Elektronika Gelombang Radio dan Gelombang Pendek
city KOTA MEDAN
province SUMATERA UTARA
shared_to_ipusnas_str 1
repoId IOS5113
first_indexed 2018-02-28T19:04:01Z
last_indexed 2018-03-19T19:08:52Z
recordtype dc
_version_ 1686309776292577280
score 17.538404