PENENTUAN BATAS LINEARITAS METODE PENGUJIAN AIR RAKSA DALAM AIR SECARA SPEKTROFOTOMETRI SERAPAN ATOM UAP DINGIN SESUAI SNI 6989.78 2011

Main Authors: Hadi, Anwar, Asiah, Asiah
Format: Article info eJournal
Bahasa: eng
Terbitan: Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL) , 2015
Subjects:
Online Access: http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171/1096
ctrlnum --ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1171
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">PENENTUAN BATAS LINEARITAS METODE PENGUJIAN AIR RAKSA DALAM AIR SECARA SPEKTROFOTOMETRI SERAPAN ATOM UAP DINGIN SESUAI SNI 6989.78 : 2011</title><creator>Hadi, Anwar</creator><creator>Asiah, Asiah</creator><subject lang="en-US">batas linearitas, kurva kalibrasi, spektrofometer serapan atom (SSA), Mercury, SNI 6989.78: 2011</subject><description lang="en-US">Rentang kerja optimal instrumen kimia untuk mengukur kadar analit yang terkandung dalam suatu contoh uji berada diantara level of quantitation (LoQ) dan level of linearity (LoL). Umumnya, laboratorium lebih mengutamakan penetapan LoQ daripada LoL karena pelaporan hasil pengujian mensyaratkan batasan LoQ yang mampu dicapai oleh laboratorium. Penelitian ini bertujuan untuk menentukan LoL metode pengujian air raksa (Mercury, Hg) dalam air dan air limbah secara spektrofotometri serapan atom sesuai SNI 6989.78: 2011 dengan kisaran kadar 1 &#x3BC;g Hg/L sampai dengan 20 &#x3BC;g Hg/L. Secara prinsip, Hg2+ direduksi oleh Sn2+ menjadi Hg0 dan selanjutnya atom tersebut dianalisis secara kuantitatif dengan SSA - uap dingin pada panjang gelombang 253,7 nm. Penentuan LoL dilakukan dengan membuat kurva kalibrasi dari larutan standar kerja sebagai uji linearitas kurva dan dilanjutkan dengan mengukur larutan kerja 1 &#x3BC;g Hg/L dan 20 &#x3BC;g Hg/L sebanyak 10 kali untuk mendapatkan nilai simpangan bakunya. Data tersebut kemudian dianalisis secara statistik menggunakan analysis of varian (anova). Uji linearitas kurva kalibrasi pada penelitian ini menghasilkan nilai multiple R = 0,999. Pada tingkat kepercayaan 99%, diperoleh Ftabel = F(0,01; 9; 9) = 5,351 sehingga Fhitung &lt; Ftabel, maka dapat disimpulkan bahwa 1 &#x3BC;g Hg/L &#x2013; 20 &#x3BC;g Hg/L merupakan regresi linear dan 20 &#x3BC;g Hg/L merupakan level of linearity (LoL) dari pengukuran Hg menggunakan SSA uap dingin sesuai dengan SNI 6989.78:2011.</description><publisher lang="en-US">Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)</publisher><contributor lang="en-US"/><date>2015-06-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>Other:</type><identifier>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171</identifier><identifier>10.20886/jklh.2015.9.1.36-45</identifier><source lang="en-US">Jurnal Ecolab; Vol 9, No 1 (2015): Jurnal Ecolab; 36-45</source><source>2502-8812</source><source>1978-5860</source><language>eng</language><relation>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171/1096</relation><rights lang="en-US">Copyright (c) 2015 Jurnal Ecolab</rights><recordID>--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1171</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
Other:
Journal:eJournal
author Hadi, Anwar
Asiah, Asiah
title PENENTUAN BATAS LINEARITAS METODE PENGUJIAN AIR RAKSA DALAM AIR SECARA SPEKTROFOTOMETRI SERAPAN ATOM UAP DINGIN SESUAI SNI 6989.78 : 2011
title_sub 2011
publisher Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)
publishDate 2015
topic batas linearitas
kurva kalibrasi
spektrofometer serapan atom (SSA)
Mercury
SNI 6989.78: 2011
url http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1171/1096
contents Rentang kerja optimal instrumen kimia untuk mengukur kadar analit yang terkandung dalam suatu contoh uji berada diantara level of quantitation (LoQ) dan level of linearity (LoL). Umumnya, laboratorium lebih mengutamakan penetapan LoQ daripada LoL karena pelaporan hasil pengujian mensyaratkan batasan LoQ yang mampu dicapai oleh laboratorium. Penelitian ini bertujuan untuk menentukan LoL metode pengujian air raksa (Mercury, Hg) dalam air dan air limbah secara spektrofotometri serapan atom sesuai SNI 6989.78: 2011 dengan kisaran kadar 1 μg Hg/L sampai dengan 20 μg Hg/L. Secara prinsip, Hg2+ direduksi oleh Sn2+ menjadi Hg0 dan selanjutnya atom tersebut dianalisis secara kuantitatif dengan SSA - uap dingin pada panjang gelombang 253,7 nm. Penentuan LoL dilakukan dengan membuat kurva kalibrasi dari larutan standar kerja sebagai uji linearitas kurva dan dilanjutkan dengan mengukur larutan kerja 1 μg Hg/L dan 20 μg Hg/L sebanyak 10 kali untuk mendapatkan nilai simpangan bakunya. Data tersebut kemudian dianalisis secara statistik menggunakan analysis of varian (anova). Uji linearitas kurva kalibrasi pada penelitian ini menghasilkan nilai multiple R = 0,999. Pada tingkat kepercayaan 99%, diperoleh Ftabel = F(0,01; 9; 9) = 5,351 sehingga Fhitung < Ftabel, maka dapat disimpulkan bahwa 1 μg Hg/L – 20 μg Hg/L merupakan regresi linear dan 20 μg Hg/L merupakan level of linearity (LoL) dari pengukuran Hg menggunakan SSA uap dingin sesuai dengan SNI 6989.78:2011.
id IOS3429.--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1171
institution Kementerian Lingkungan Hidup dan Kehutanan Republik Indonesia
institution_id 475
institution_type library:special
library
library Perpustakaan Kementerian Lingkungan Hidup dan Kehutanan RI
library_id 121
collection Indonesian Journal of Forestry Research
repository_id 3429
subject_area Kehutanan
Lingkungan
Pertanian
city BOGOR
province JAWA BARAT
repoId IOS3429
first_indexed 2016-09-28T01:15:49Z
last_indexed 2016-09-28T01:15:49Z
recordtype dc
_version_ 1764501241475366912
score 17.538404