Comparisons of Water-Equivalent Diameter Measured on Images of Abdominal Routine Computed Tomography with and without A Contrast Agent

Main Authors: Nitasari, A.; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia, Anam, C.; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia, Budi, W. S.; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia, Wati, A. L.; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia, Syarifudin, S; Department of Radiology, Dr. Kariadi Hospital, Jl. Dr. Sutomo No.19, Semarang Selatan, Semarang 50244, Indonesia, Dougherty, G.; Department of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA, USA
Other Authors: World Class Research University (WCRU), Diponegoro University, 2021
Format: Article info application/pdf eJournal
Bahasa: eng
Terbitan: PPIKSN-BATAN , 2021
Subjects:
Online Access: http://aij.batan.go.id/index.php/aij/article/view/1112
http://aij.batan.go.id/index.php/aij/article/view/1112/984
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1919
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1931
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1932
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1933
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1934
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1935
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1936
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1937
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1938
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1939
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1944
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1945
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1946
http://aij.batan.go.id/index.php/aij/article/downloadSuppFile/1112/1947
Daftar Isi:
  • The size-specific dose estimate (SSDE) is a metric for an estimation of patient dose in computed tomography (CT). The SSDE strongly depends on the water-equivalent diameter (DW). In abdominal CT examinations, a contrast agent is sometimes used to more clearly visualize tissue lesions. The Hounsfield unit (HU) of CT images with and without the use of a contrast agent at specific areas is slightly different and it may affect the DW value. This study aimed to compare the DW values calculated from axial CT images in patients who had undergone routine abdominal scans both with and without the use of a contrast agent. Axial images of 144 patients with a weight range of 3.5 kg to 90 kg who had undergone routine abdominal scans both with and without the use of a contrast agent using a Siemens Sensation 64 CT scanner were retrospectively collected. The DW values were automatically calculated using the Matlab-based IndoseCT (version 15a) software. The results show the percentage difference between DW,contrast and DW,non-contrast is below 2 %.As a result, the mean SSDEcontrast is 1.5 % smaller than SSDEnon-contrast. Due to the effect of a contrast agent on the DW and SSDE values is below 2 %, the axial images of CT abdomen without the use of a contrast agent can be used as the accurate estimation of DW and SSDE for images with the use of a contrast agent.