ANALISA PENGARUH DIAMETER KAWAT TERHADAP TEMPERATUR KERJA MOTOR INDUKSI SATU PHASA
Daftar Isi:
- With the technology of the industrial world at this time led to the increasing need for induction motors are increasingly more interested by industry players. This is because in the world of motor induction industry is the easiest maintenance and efficient use, the induction motor in the classification is divided into two namely motor induction one phase and three phase induction motor. On the operating system, motor induction one often experienced excessive heat as a result of the use of loads that do not conform to the construction of the motor. Due to excessive heat, it causes the quality of insulators on the wire of the conductor decreases and can result in damage to the induction motor. One of the other factors of overheating is the diameter of a small stator wire that makes an increase in the barrier value of the sender wire. However, not all wire conducter causes overheating, the solution is to replace the diameter of the copper wire is larger than the standard size because it can lower the value of the resistance. Therefore, it is necessary to learn more about the influence of the diameter of the wire to the working temperature of the motor induction one Phasa. From this test in the result of measurement and calculation of the work temperature of the induction motor on the third motor with the diameter of the wire coil of stator 0.55 mm smaller, than the motor one and the two motors. Based on this, it can be concluded that the diameter of the wire can affect the value of obstacles that cause an increase in the working temperature of an induction motor.