Experimental stability boundary for a three-flute 20 mm indexable end mill in slot machining of aluminium 7075-T651
Main Author: | Eynian, Mahdi |
---|---|
Format: | Dataset |
Terbitan: |
Mendeley
, 2019
|
Subjects: | |
Online Access: |
https:/data.mendeley.com/datasets/c6c9tjvy8g |
Daftar Isi:
- Chatter test Results along with impact test results on the tool mounted on the spindle of the DMC160 machine tool, in the stationary condition. The chatter tests spans 7500-9500 rev/min and depth of cuts of 0.25 to 1.2 mm.