Gas sensor array temperature modulation

Main Author: Burgués, Javier
Format: Dataset
Terbitan: Mendeley , 2019
Subjects:
Online Access: https:/data.mendeley.com/datasets/8fgnf9v5f5
Daftar Isi:
  • A chemical detection platform composed of 14 temperature-modulated metal oxide semiconductor (MOX) gas sensors was continuously exposed during 3 weeks to dynamic mixtures of carbon monoxide (CO) and humid synthetic air in a gas chamber. The utilized sensors are commercially available by Figaro Engineering (7 units of TGS 3870-A04) and FIS (7 units of SB-500-12). The heater voltage of the sensors is modulated in the range 0.2-0.9 V in cycles of 20 and 25 s, following manufacturer recommendations. The acquired time series of the sensors and the measured values of CO concentration, humidity and temperature inside the gas chamber are provided. Each experiment consists on 100 measurements: 10 experimental concentrations uniformly distributed in the range 0-20 ppm and 10 replicates per concentration. Each replicate has a relative humidity randomly chosen from a uniform distribution between 15% and 75% r.h. A single experiment lasts 25 hours (100 samples x 15 minutes/sample) and was replicated on 13 working days spanning a natural period of 17 days. ##Attribute Information## The dataset is presented in 13 text files, where each file corresponds to a different measurement day. The filenames indicate the timestamp (yyyymmdd_HHMMSS) of the start of the measurements. Each file includes the acquired time series, presented in 20 columns: Time (s), CO concentration (ppm), Humidity (%r.h.), Temperature (oC), Flow rate (mL/min), Heater voltage (V), and the resistance of the 14 gas sensors: R1 (MOhm),R2 (MOhm),R3 (MOhm),R4 (MOhm),R5 (MOhm),R6 (MOhm),R7 (MOhm),R8 (MOhm),R9 (MOhm),R10 (MOhm),R11 (MOhm),R12 (MOhm),R13 (MOhm),R14 (MOhm) Resistance values R1-R7 correspond to FIGARO TGS 3870 A-04 sensors, whereas R8-R14 correspond to FIS SB-500-12 units. ##Relevant Papers## The description of the experimental setup and chemical detection platform can be found in [1-2]. The dataset has been used also in [3]. [1] Burgués, Javier, Juan Manuel Jiménez-Soto, and Santiago Marco. "Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models." Analytica chimica acta 1013 (2018): 13-25. [2] Burgués, Javier, and Santiago Marco. "Multivariate estimation of the limit of detection by orthogonal partial least squares in temperature-modulated MOX sensors." Analytica chimica acta 1019 (2018): 49-64. [3] Fernandez, Luis, Jia Yan, Jordi Fonollosa, Javier Burgués, Agustin Gutierrez, and Santiago Marco. "A practical method to estimate the resolving power of a chemical sensor array: application to feature selection." Frontiers in chemistry 6 (2018). ##Citation Request## Citing references [1] and [2] is requested if you use the dataset. ##Donors of the Dataset## - Javier Burgués (jburgues '@'ibecbarcelona.eu, jburgues8 '@'gmail.com) - Santiago Marco (smarco '@'ibecbarcelona.eu)