Experimental and Numerical Analysis of Spun Pile-to-Pile Cap Connection with Reinforced Concrete Infill under Cyclic Loading
Main Authors: | Tandita, Alfetra Henoch, Lase, Yuskar, Prakoso, Widjojo Adi, Orientilize, Mulia |
---|---|
Format: | Article info application/pdf eJournal |
Bahasa: | eng |
Terbitan: |
Department of Civil Engineering, Faculty of Engineering, Universitas Brawijaya
, 2022
|
Subjects: | |
Online Access: |
https://rekayasasipil.ub.ac.id/index.php/rs/article/view/978 https://rekayasasipil.ub.ac.id/index.php/rs/article/view/978/547 |
Daftar Isi:
- Numerical study was conducted by using ABAQUS software to investigate two issues on spun pile connections. The issues are usage of non-shrinkage concrete infill cast inside hollow of pile and ductility. An experimental test was carried out to investigate the effect of two different concrete infill types which were common concrete fcâ€TM 35 MPa and non-shrinkage concrete fcâ€TM 54 MPa. A finite element model was validated against experimental test. The results were compared in terms of hysteresis curve, ductility, and performance level. Ductility is one of the important parameters to describe performance of spun pile connections under seismic load. There are different approaches to calculate ductility and this leads to four different ductility values. Hence, ductility of spun pile with concrete infill is in the range of 3.2 to 4.8. Behavior of spun pile with non-shrinkage concrete infill is slightly improved although the results were almost similar.