ANALISIS KOORDINASI SETTING RELAY PROTEKSI OCR, GFR DAN RECLOSER SETELAH PENAMBAHAN FEEDER PADA JARINGAN DISTRIBUSI 20 KV

Main Author: ZARAWI, MUHAMMAD IQBAL
Format: Thesis NonPeerReviewed Book
Bahasa: ind
Terbitan: , 2020
Subjects:
Online Access: http://repository.mercubuana.ac.id/55816/1/01%20HALAMAN%20JUDUL.pdf
http://repository.mercubuana.ac.id/55816/2/02%20ABSTRAK__.pdf
http://repository.mercubuana.ac.id/55816/3/03%20lembar%20pernyataan.pdf
http://repository.mercubuana.ac.id/55816/4/04%20lembar%20pengesahan.pdf
http://repository.mercubuana.ac.id/55816/5/05%20HALAMAN%20KATA%20PENGANTAR.pdf
http://repository.mercubuana.ac.id/55816/6/06%20DAFTAR%20ISI.pdf
http://repository.mercubuana.ac.id/55816/8/07%20DAFTAR%20TABEL.pdf
http://repository.mercubuana.ac.id/55816/9/08%20DAFTAR%20GAMBAR.pdf
http://repository.mercubuana.ac.id/55816/10/09%20DAFTAR%20ISTILAH.pdf
http://repository.mercubuana.ac.id/55816/11/10%20TA-Bab%20I.pdf
http://repository.mercubuana.ac.id/55816/12/11%20TA-Bab%20II.pdf
http://repository.mercubuana.ac.id/55816/13/12%20TA-Bab%20III.pdf
http://repository.mercubuana.ac.id/55816/14/13%20TA-Bab%20IV.pdf
http://repository.mercubuana.ac.id/55816/15/14%20TA-Bab%20V.pdf
http://repository.mercubuana.ac.id/55816/16/15%20DAFTAR%20PUSTAKA.pdf
http://repository.mercubuana.ac.id/55816/17/16%20Lampiran.pdf
http://repository.mercubuana.ac.id/55816/
ctrlnum 55816
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://repository.mercubuana.ac.id/55816/</relation><title>ANALISIS KOORDINASI SETTING RELAY PROTEKSI OCR, GFR DAN RECLOSER SETELAH PENAMBAHAN FEEDER PADA JARINGAN DISTRIBUSI 20 KV</title><creator>ZARAWI, MUHAMMAD IQBAL</creator><subject>005.754 Network Databases/Pangakalan Data Jaringan</subject><subject>620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan</subject><subject>621 Applied Physics/Fisika terapan</subject><subject>621.3 Electrical Engineering, Lighting, Superconductivity, Magnetic Engineering, Applied Optics, Paraphotic Technology, Electronics Communications Engineering, Computers/Teknik Elektro, Pencahayaan, Superkonduktivitas, Teknik Magnetik, Optik Terapan, Tekn</subject><description>The Distribution system is part of electrical power system that serves to deliver electricity from 150/20 kV Substationto consumers. Pudakpayung 60 MVA Substation has 5 feeders, in 2016 there is a new feeder with code PDP 5.One form of fault inthe power distribution system is short circuit. To overcome the short circuit in the distribution system require a reliable protection system. Relay setting and relay coordination is one of the requirements of protection system reliability.This final project evaluating the relay setting and relay coordination of OCR, GFR and Recloser Pudakpayung Substation feeder after the addition of feeder PDP 5. The evaluation results using ETAP 12.6.0 shows the condition of the existing coordination between the relay protection equipment at feeder PDP when there is a maximum current fault with incoming relay TMS value OCR=0,3 and GFR=0,43also outgoing relay TMS value OCR = 0,27 and GFR = 0,41.The existing protection coordination is not in accordance with the IEEE 242-1986standard by the grading time 0.3-0.4seconds and there is no coordination curves precede and overlap. After the relay coordination adjusted by changing the Iset and TMS of the relay so the incoming relay TMS value OCR=0,423and GFR=0,545;outgoing relayPDP 2TMS value OCR = 0,389and GFR = 0,448; and outgoing relay PDP 1,3,4,5,6 OCR = 0,34 and GFR = 0,415.Keywords: Distribution System, short circuit fault, relay, recloser&#xD; &#xD; Sistem distribusi merupakan bagian dari sistem tenaga listrik yang berfungsi untuk menyalurkan tenaga listrik dari Gardu Induk 150/20 kV ke konsumen. GISPudakpayung 60 MVA mempunyai 5 penyulang, pada tahun 2016 dilakukan penambahan penyulang yaitupenyulang PDP 5. Salah satu bentuk gangguan yang terjadi pada sistem distribusi tenaga listrik adalah gangguan hubung singkat. Untuk mengatasi gangguan hubung singkat pada sistem distribusi maka diperlukansistem proteksi yang handal. Setting relaydan koordinasi relayadalah salah satu syarat keandalan sistem proteksi. Pada tugas akhir ini dilakukan evaluasi setting proteksi OCR, GFR dan recloser penyulang GISPudakpayung setelah adanya penambahan penyulang PDP 5. Hasil evaluasi dengan menggunakan program ETAP 12.6.0 menunjukkan kondisi eksisting koordinasi relayantar peralatan proteksi pada penyulang PDP ketika terjadi gangguan pada arus gangguan maksimal dengan nilai TMS relayIncoming OCR = 0,3 dan GFR = 0,43 serta nilai TMS relayoutgoing OCR = 0,27 dan GFR=0,41. Koordinasi proteksi kondisi eksisting belum sesuai dengan standar IEEE 242-1986 dimana grading time antar peralatan proteksi adalah 0,3-0,4detik dan tidak ada kurva koordinasi yangsaling memotong dan mendahului. Setelah dilakukan perbaikan koordinasi relaydengan mengubah Iset dan TMS relaysehingga nilai TMS relayincoming OCR= 0,423dan GFR= 0,545;nilai TMS relayoutgoing PDP 2 OCR=0,389dan GFR = 0,448; dan nilai TMS relay outgoing PDP 1,3,4,5,6 = OCR = 0,34,dan GFR = 0,415.Kata kunci : Sistem Distribusi, Gangguan Hubung Singkat,Relay, Recloser</description><date>2020-05-12</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/1/01%20HALAMAN%20JUDUL.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/2/02%20ABSTRAK__.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/3/03%20lembar%20pernyataan.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/4/04%20lembar%20pengesahan.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/5/05%20HALAMAN%20KATA%20PENGANTAR.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/6/06%20DAFTAR%20ISI.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/8/07%20DAFTAR%20TABEL.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/9/08%20DAFTAR%20GAMBAR.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/10/09%20DAFTAR%20ISTILAH.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/11/10%20TA-Bab%20I.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/12/11%20TA-Bab%20II.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/13/12%20TA-Bab%20III.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/14/13%20TA-Bab%20IV.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/15/14%20TA-Bab%20V.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/16/15%20DAFTAR%20PUSTAKA.pdf</identifier><type>Book:Book</type><language>ind</language><identifier>http://repository.mercubuana.ac.id/55816/17/16%20Lampiran.pdf</identifier><identifier> ZARAWI, MUHAMMAD IQBAL (2020) ANALISIS KOORDINASI SETTING RELAY PROTEKSI OCR, GFR DAN RECLOSER SETELAH PENAMBAHAN FEEDER PADA JARINGAN DISTRIBUSI 20 KV. S1-Sarjana thesis, Universitas Mercu Buana Jakarta. </identifier><recordID>55816</recordID></dc>
language ind
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author ZARAWI, MUHAMMAD IQBAL
title ANALISIS KOORDINASI SETTING RELAY PROTEKSI OCR, GFR DAN RECLOSER SETELAH PENAMBAHAN FEEDER PADA JARINGAN DISTRIBUSI 20 KV
publishDate 2020
topic 005.754 Network Databases
Pangakalan Data Jaringan
620 Engineering and Applied Operations
Ilmu Teknik dan operasi Terapan
621 Applied Physics
Fisika terapan
621.3 Electrical Engineering
Lighting
Superconductivity
Magnetic Engineering
Applied Optics
Paraphotic Technology
Electronics Communications Engineering
Computers/Teknik Elektro
Pencahayaan
Superkonduktivitas
Teknik Magnetik
Optik Terapan
Tekn
url http://repository.mercubuana.ac.id/55816/1/01%20HALAMAN%20JUDUL.pdf
http://repository.mercubuana.ac.id/55816/2/02%20ABSTRAK__.pdf
http://repository.mercubuana.ac.id/55816/3/03%20lembar%20pernyataan.pdf
http://repository.mercubuana.ac.id/55816/4/04%20lembar%20pengesahan.pdf
http://repository.mercubuana.ac.id/55816/5/05%20HALAMAN%20KATA%20PENGANTAR.pdf
http://repository.mercubuana.ac.id/55816/6/06%20DAFTAR%20ISI.pdf
http://repository.mercubuana.ac.id/55816/8/07%20DAFTAR%20TABEL.pdf
http://repository.mercubuana.ac.id/55816/9/08%20DAFTAR%20GAMBAR.pdf
http://repository.mercubuana.ac.id/55816/10/09%20DAFTAR%20ISTILAH.pdf
http://repository.mercubuana.ac.id/55816/11/10%20TA-Bab%20I.pdf
http://repository.mercubuana.ac.id/55816/12/11%20TA-Bab%20II.pdf
http://repository.mercubuana.ac.id/55816/13/12%20TA-Bab%20III.pdf
http://repository.mercubuana.ac.id/55816/14/13%20TA-Bab%20IV.pdf
http://repository.mercubuana.ac.id/55816/15/14%20TA-Bab%20V.pdf
http://repository.mercubuana.ac.id/55816/16/15%20DAFTAR%20PUSTAKA.pdf
http://repository.mercubuana.ac.id/55816/17/16%20Lampiran.pdf
http://repository.mercubuana.ac.id/55816/
contents The Distribution system is part of electrical power system that serves to deliver electricity from 150/20 kV Substationto consumers. Pudakpayung 60 MVA Substation has 5 feeders, in 2016 there is a new feeder with code PDP 5.One form of fault inthe power distribution system is short circuit. To overcome the short circuit in the distribution system require a reliable protection system. Relay setting and relay coordination is one of the requirements of protection system reliability.This final project evaluating the relay setting and relay coordination of OCR, GFR and Recloser Pudakpayung Substation feeder after the addition of feeder PDP 5. The evaluation results using ETAP 12.6.0 shows the condition of the existing coordination between the relay protection equipment at feeder PDP when there is a maximum current fault with incoming relay TMS value OCR=0,3 and GFR=0,43also outgoing relay TMS value OCR = 0,27 and GFR = 0,41.The existing protection coordination is not in accordance with the IEEE 242-1986standard by the grading time 0.3-0.4seconds and there is no coordination curves precede and overlap. After the relay coordination adjusted by changing the Iset and TMS of the relay so the incoming relay TMS value OCR=0,423and GFR=0,545;outgoing relayPDP 2TMS value OCR = 0,389and GFR = 0,448; and outgoing relay PDP 1,3,4,5,6 OCR = 0,34 and GFR = 0,415.Keywords: Distribution System, short circuit fault, relay, recloser Sistem distribusi merupakan bagian dari sistem tenaga listrik yang berfungsi untuk menyalurkan tenaga listrik dari Gardu Induk 150/20 kV ke konsumen. GISPudakpayung 60 MVA mempunyai 5 penyulang, pada tahun 2016 dilakukan penambahan penyulang yaitupenyulang PDP 5. Salah satu bentuk gangguan yang terjadi pada sistem distribusi tenaga listrik adalah gangguan hubung singkat. Untuk mengatasi gangguan hubung singkat pada sistem distribusi maka diperlukansistem proteksi yang handal. Setting relaydan koordinasi relayadalah salah satu syarat keandalan sistem proteksi. Pada tugas akhir ini dilakukan evaluasi setting proteksi OCR, GFR dan recloser penyulang GISPudakpayung setelah adanya penambahan penyulang PDP 5. Hasil evaluasi dengan menggunakan program ETAP 12.6.0 menunjukkan kondisi eksisting koordinasi relayantar peralatan proteksi pada penyulang PDP ketika terjadi gangguan pada arus gangguan maksimal dengan nilai TMS relayIncoming OCR = 0,3 dan GFR = 0,43 serta nilai TMS relayoutgoing OCR = 0,27 dan GFR=0,41. Koordinasi proteksi kondisi eksisting belum sesuai dengan standar IEEE 242-1986 dimana grading time antar peralatan proteksi adalah 0,3-0,4detik dan tidak ada kurva koordinasi yangsaling memotong dan mendahului. Setelah dilakukan perbaikan koordinasi relaydengan mengubah Iset dan TMS relaysehingga nilai TMS relayincoming OCR= 0,423dan GFR= 0,545;nilai TMS relayoutgoing PDP 2 OCR=0,389dan GFR = 0,448; dan nilai TMS relay outgoing PDP 1,3,4,5,6 = OCR = 0,34,dan GFR = 0,415.Kata kunci : Sistem Distribusi, Gangguan Hubung Singkat,Relay, Recloser
id IOS5909.55816
institution Universitas Mercu Buana
institution_id 134
institution_type library:university
library
library Perpustakaan Universitas Mercu Buana
library_id 542
collection Repository Universitas Mercu Buana
repository_id 5909
subject_area Econmics/Ilmu Ekonomi
Communication/Komunikasi
Engineering/Ilmu Teknik
Measurement/Teknik Desain, Pengujian, Pengukuran, Kualitas, Perawatan, Pemeliharaan, Perbaikan
city Jakarta Barat
province DKI JAKARTA
shared_to_ipusnas_str 1
repoId IOS5909
first_indexed 2020-05-26T03:14:53Z
last_indexed 2020-06-16T14:17:36Z
recordtype dc
_version_ 1685794935356260352
score 17.538404