MAINTENANCE POMPA RECIPROCATING 211/212 PM-4 A/B MENGGUNAKAN METODE RCM DI PT PERTAMINA (PERSERO) REFINERY UNIT II DUMAI
Main Authors: | Mesra, Trisna, Melliana, Melliana, Fitra, Fitra, Amanda, Rizki |
---|---|
Format: | Article info eJournal |
Bahasa: | eng |
Terbitan: |
Universitas Islam Sumatera Utara
, 2018
|
Online Access: |
https://jurnal.uisu.ac.id/index.php/but/article/view/535 https://jurnal.uisu.ac.id/index.php/but/article/view/535/468 |
ctrlnum |
--jurnal.uisu.ac.id-index.php-index-oai:article-535 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">MAINTENANCE POMPA RECIPROCATING 211/212 PM-4 A/B MENGGUNAKAN METODE RCM DI PT PERTAMINA (PERSERO) REFINERY UNIT II DUMAI</title><creator>Mesra, Trisna</creator><creator>Melliana, Melliana</creator><creator>Fitra, Fitra</creator><creator>Amanda, Rizki</creator><description lang="en-US">Pompa Reciprocating 211/212 PM-34 A/B berfungsi mengalirkan fluida berupa diesel oil yang  dialirkan ke 211/212 PRT-3 di mana diesel tersebut berfungsi sebagai pelumas mechanical seal 211/212 PRT-3. Pompa ini sering mengalami kerusakan pada komponen packing silinder yang sering bocor yang mengakibatkan terganggunya sistem lubrikasi pada mechanical seal 211/212 PRT-3. Pada penelitian ini penulis menggunakan metode RCM (Reliablity Centered Maintenance) yang mana metode ini merupakan metode kualitatif yang memanfaatkan informasi dari setiap komponen-komponen peralatan yang berkenaan dengan kehandalan dan kelemahannya lalu menentukan tindakan perawatan yang harus dipilih. Hasil dari penelitian ini peneliti menemukan solusi bahwa tindakan perawatan Pompa Reciprocating 211/212 PM-34 A/B yang harus dilakukan diantaranya adalah Condition directed (63,64 % dari keseluruhan komponen), failure finding (13,64 % dari keseluruhan komponen), dan run to failure (22,72 % dari keseluruhan komponen). Berdasarkan penelitian ini diperoleh kesimpulan bahwa cara mengimplementasikan metode RCM yang telah distandarkan oleh Smith (1992) pada pompa reciprocating 211/212 PM-34 A/B yaitu melakukan pemilihan sistem dan pengumpulan informasi, mendefinisikan batasan sistem, mendeskripsikan sistem dan functional diagram blok, penentuan fungsi sistem dan kegagalan fungsi, Failure Mode and Effect Analysis (FMEA), Logic Tree Analysis (LTA), dan task selection.</description><publisher lang="en-US">Universitas Islam Sumatera Utara</publisher><contributor lang="en-US"/><date>2018-06-23</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Journal:Article</type><type>Other:</type><identifier>https://jurnal.uisu.ac.id/index.php/but/article/view/535</identifier><source lang="en-US">Buletin Utama Teknik; Vol 13, No 3 (2018): Edisi Mei; 175-183</source><source>2598-3814</source><source>1410-4520</source><language>eng</language><relation>https://jurnal.uisu.ac.id/index.php/but/article/view/535/468</relation><rights lang="en-US">Copyright (c) 2018 Buletin Utama Teknik</rights><recordID>--jurnal.uisu.ac.id-index.php-index-oai:article-535</recordID></dc>
|
language |
eng |
format |
Journal:Article Journal Other:info:eu-repo/semantics/publishedVersion Other Other: Journal:eJournal |
author |
Mesra, Trisna Melliana, Melliana Fitra, Fitra Amanda, Rizki |
title |
MAINTENANCE POMPA RECIPROCATING 211/212 PM-4 A/B MENGGUNAKAN METODE RCM DI PT PERTAMINA (PERSERO) REFINERY UNIT II DUMAI |
publisher |
Universitas Islam Sumatera Utara |
publishDate |
2018 |
url |
https://jurnal.uisu.ac.id/index.php/but/article/view/535 https://jurnal.uisu.ac.id/index.php/but/article/view/535/468 |
contents |
Pompa Reciprocating 211/212 PM-34 A/B berfungsi mengalirkan fluida berupa diesel oil yang dialirkan ke 211/212 PRT-3 di mana diesel tersebut berfungsi sebagai pelumas mechanical seal 211/212 PRT-3. Pompa ini sering mengalami kerusakan pada komponen packing silinder yang sering bocor yang mengakibatkan terganggunya sistem lubrikasi pada mechanical seal 211/212 PRT-3. Pada penelitian ini penulis menggunakan metode RCM (Reliablity Centered Maintenance) yang mana metode ini merupakan metode kualitatif yang memanfaatkan informasi dari setiap komponen-komponen peralatan yang berkenaan dengan kehandalan dan kelemahannya lalu menentukan tindakan perawatan yang harus dipilih. Hasil dari penelitian ini peneliti menemukan solusi bahwa tindakan perawatan Pompa Reciprocating 211/212 PM-34 A/B yang harus dilakukan diantaranya adalah Condition directed (63,64 % dari keseluruhan komponen), failure finding (13,64 % dari keseluruhan komponen), dan run to failure (22,72 % dari keseluruhan komponen). Berdasarkan penelitian ini diperoleh kesimpulan bahwa cara mengimplementasikan metode RCM yang telah distandarkan oleh Smith (1992) pada pompa reciprocating 211/212 PM-34 A/B yaitu melakukan pemilihan sistem dan pengumpulan informasi, mendefinisikan batasan sistem, mendeskripsikan sistem dan functional diagram blok, penentuan fungsi sistem dan kegagalan fungsi, Failure Mode and Effect Analysis (FMEA), Logic Tree Analysis (LTA), dan task selection. |
id |
IOS5112.--jurnal.uisu.ac.id-index.php-index-oai:article-535 |
institution |
Universitas Islam Sumatera Utara |
institution_id |
1254 |
institution_type |
library:university library |
library |
Universitas Islam Sumatera Utara |
library_id |
1095 |
collection |
Buletin Utama Teknik |
repository_id |
5112 |
subject_area |
Electronics/Teknik Elektronika Teknik Industri, Mesin Teknik Informatika Civil Engineering/Teknik Sipil |
city |
KOTA MEDAN |
province |
SUMATERA UTARA |
shared_to_ipusnas_str |
1 |
repoId |
IOS5112 |
first_indexed |
2018-07-10T07:29:25Z |
last_indexed |
2018-07-10T07:29:25Z |
recordtype |
dc |
_version_ |
1686309612556386304 |
score |
17.538404 |