The Study Of Effects Of Electrolysis Variables To The Inherent Moisture Content In Brown Coal
Main Author: | Bustan, M. Djoni |
---|---|
Format: | Article PeerReviewed application/pdf |
Terbitan: |
, 2007
|
Subjects: | |
Online Access: |
http://eprints.unsri.ac.id/1574/1/The_study_of_effects_of.pdf http://eprints.unsri.ac.id/1574/ |
Daftar Isi:
- This research uses Electrothermal Dewatering Brown Coal (EDBC) technology to reduce the inherent moisture content in brown coal using kerosene as coal slurry medium maker. The purpode of this research is to learn the effect of voltage and process temperature to the increasing of coal product quality. From this research analysis of product at energy development and Mining Depatement of South Sumatera province shown that lowness inherent moisture product of experiment as 2.64% (adb) with beginning inherent moisture 12.09% (adb) that happen deriving inherent moisture as big as 78.16%. Lowness inherent moisture got from experiment use ratio of coal and kerosene at 1 : 2 and variable of electrolysis at 12 volts.