PERENCANAAN ULANG BANGUNAN ATAS HOTEL IBIS MALANG DENGAN MENGGUNAKAN SISTEM BALOK GRID
Main Author: | FAIZIN, FAIZIN |
---|---|
Format: | Thesis NonPeerReviewed |
Terbitan: |
, 2013
|
Subjects: | |
Online Access: |
http://eprints.umm.ac.id/15277/ |
Daftar Isi:
- Grid structure is a space frame structure that used on a large expanse, which consists of several beams are formed in such a way that the structure can hod deflection because of the work load. From the calculation of the structure of the roof and floor plates with plate thickness of 10 cm acquired reinforcement à ̃10-150 mm for reinforcement pedestal and field, as well as for reinforcing à ̃8-250 shrinkage. Grid structure dimensions is 20x30 cm for grid roof and 20x40 cm for grid floor, with reinforcing beams on the pedestal 5D16 and 4D16 on the field with the cross bar ̃10 - 90 mm. Main beam is planned with dimensions of 35x70 cm, with reinforcement beam using D29 and D25 principal reinforcement with reinforcement ̃12 stirrups. on the planning of column is used the dimensions 65x100 cm with 4 sides 6D32 reinforcement on the edge of the portal columns X and Y directions, and the center column portal 8D32 X and Y directions with reinforcing cross bar D10 - 200 mm. On the planning of shear walls is used of reinforcement with 2 layers of reinforcement 17D16-450 mm for floors 9-12, reinforcement 19D16-400 mm for floors 5-8 and reinforcement 26D16-300 mm for floors 1-4.