Perbandingan Sifat Fisik Beton Yang Menggunakan Semen Portland Pozzolan Dan Semen Portland Tipe I
Main Author: | Yusnita, Heni |
---|---|
Other Authors: | M. Syukur |
Format: | Student Papers |
Bahasa: | ind |
Subjects: | |
Online Access: |
http://repository.usu.ac.id/handle/123456789/30255 |
Daftar Isi:
- The research about concrete by using the Portland pozzolan cement and Portland cement type I has been done with the variation of submersion time is 7, 14, 21, and 28 days. The test is done for physics of the concrete. The sample is made from the ingredients 1 cement : 2 sand : 3 pebble. The result of the researching shows that the used of the Portland pozzolan cement can raise the impact of the concrete as much as 9,15% from concrete which uses the Portland cement type I. Orther side for the water absorbtion and porositas by using the Portland pozzolan cement is begun from 0,96 % to 20,31% and from 0% to 19,74%, higher than the concrete which uses the Portland cement type I.