Daftar Isi:
  • High body temperatutre which make the chicken has limited ability to adjust to the ambient temeprature. Therefore the chicken will feel very depressed if the ambient temperature is 19-30 degrees . Brilers mantanance issues arise production resukt then house opned . Improve technology adn control sytem closed house thoroghly mayor impact for incrense production . The purpose of this study is 1) Modeling heat trasfer in closed broiler house system with mathematical equations and laplace function of time. 2) Simulate the temperature control system based on a brolier house closed fuzzy logic. Fuzzy logic control system response result rise time, percent surge, sedentary time, steady sate error, delay time responding suistanable with parameter response. Result of testing on the model desired temperature within the maintanance period in the three scenarios starter, grower adn finisher can be obtanied with good isolation without significant disruption. The broiler closed house heater power starter peroid on average 297.000 watts and future grower, finisher requires 5.400 watts