Main Authors: Lestari, Retno Puji, Gifrianto, Resi, Hadi, Anwar
Format: Article info application/pdf eJournal
Bahasa: ind
Terbitan: Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL) , 2017
Subjects:
Online Access: http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088/2220
ctrlnum --ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-3088
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US"/><title lang="id-ID">PENENTUAN LIMIT DETEKSI PENGUJIAN GAS HIDROGEN KLORIDA (HCl) DARI EMISI SUMBER TIDAK BERGERAK MENGGUNAKAN KROMATOGRAFI ION</title><creator>Lestari, Retno Puji</creator><creator>Gifrianto, Resi</creator><creator>Hadi, Anwar</creator><subject lang="en-US"/><subject lang="id-ID">hidrogen klorida; emisi sumber tidak bergerak; kromatografi ion</subject><description lang="en-US"/><description lang="id-ID">Pengujian kadar gas hidrogen klorida (HCl) dari emisi sumber tidak bergerak yang dilakukan oleh laboratoriumlaboratorium lingkungan di Indonesia mengacu pada SNI 19-7117.8-2005. Di dalam metode spektrofotometri tersebut digunakan beberapa bahan berbahaya dan beracun (B3) antara lain merkuri tiosianat, metanol,dan asam perklorat. Laboratorium P3KLL menentukan limit deteksi terhadap metode uji yang diadopsi dari JIS K 0107-1995 menggunakan instrumen kromatografi ion DIONEX ICS5000. Instrumen IC5000 dilengkapi dengan detektor konduktivitas, penggunaan EGC (Eluent Generator Cartridge) yang ditambahkan dengan Carbonate Removal, dan mempunyai ukuran loop sampel 50&#x3BC;L. Kolom separator IonPac AS18 dengan kolom penjaga IonPAc AG18 dan suppressor ASRS-II digunakan pada suhu 350C. Larutan yang digunakan sebagai eluen adalah H O (DHL&lt; 1&#x3BC;S/cm) 2 pada laju alir 1 L/menit. Tahapan kegiatan terdiri dari persiapan, pengambilan contoh uji dan validasi metoda. Pengambilan contoh uji dilakukan tiga kali di insenerator sebagai bagian dari tahapan validasi yaitu mengkonfirmasi rentang uji. Dari hasil kajian tersebut, diperoleh LoD = 0,6 mg/Nm3, LoQ = 2 mg/Nm3, danLoL= 129 mg/Nm3, dimana JIS K 0107-1995 &#x201C;Methods for Determination of Hydrogen Chloride in Flue Gas&#x201D;memiliki rentang kerja 0,6 &#x2013; 130 mg/Nm3. Disimpulkan bahwa metode terverifikasi sesuai tujuan dan laboratorium P3KLL mampu menunjukkan kompetensinya dalam menerapkan metode pengujian Hcl tersebut.</description><publisher lang="en-US">Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)</publisher><contributor lang="en-US"/><contributor lang="id-ID"/><date>2017-07-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>File:application/pdf</type><identifier>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088</identifier><identifier>10.20886/jklh.2017.11.1.32-41</identifier><source lang="en-US">Jurnal Ecolab; Vol 11, No 1 (2017): Jurnal Ecolab; 32-41</source><source lang="id-ID">Jurnal Ecolab; Vol 11, No 1 (2017): Jurnal Ecolab; 32-41</source><source>2502-8812</source><source>1978-5860</source><language>ind</language><relation>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088/2220</relation><rights lang="en-US">Copyright (c) 2017 Jurnal Ecolab</rights><rights lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</rights><recordID>--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-3088</recordID></dc>
language ind
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
Other:
File:application/pdf
File
Journal:eJournal
author Lestari, Retno Puji
Gifrianto, Resi
Hadi, Anwar
publisher Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)
publishDate 2017
topic hidrogen klorida
emisi sumber tidak bergerak
kromatografi ion
url http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/3088/2220
contents Pengujian kadar gas hidrogen klorida (HCl) dari emisi sumber tidak bergerak yang dilakukan oleh laboratoriumlaboratorium lingkungan di Indonesia mengacu pada SNI 19-7117.8-2005. Di dalam metode spektrofotometri tersebut digunakan beberapa bahan berbahaya dan beracun (B3) antara lain merkuri tiosianat, metanol,dan asam perklorat. Laboratorium P3KLL menentukan limit deteksi terhadap metode uji yang diadopsi dari JIS K 0107-1995 menggunakan instrumen kromatografi ion DIONEX ICS5000. Instrumen IC5000 dilengkapi dengan detektor konduktivitas, penggunaan EGC (Eluent Generator Cartridge) yang ditambahkan dengan Carbonate Removal, dan mempunyai ukuran loop sampel 50μL. Kolom separator IonPac AS18 dengan kolom penjaga IonPAc AG18 dan suppressor ASRS-II digunakan pada suhu 350C. Larutan yang digunakan sebagai eluen adalah H O (DHL< 1μS/cm) 2 pada laju alir 1 L/menit. Tahapan kegiatan terdiri dari persiapan, pengambilan contoh uji dan validasi metoda. Pengambilan contoh uji dilakukan tiga kali di insenerator sebagai bagian dari tahapan validasi yaitu mengkonfirmasi rentang uji. Dari hasil kajian tersebut, diperoleh LoD = 0,6 mg/Nm3, LoQ = 2 mg/Nm3, danLoL= 129 mg/Nm3, dimana JIS K 0107-1995 “Methods for Determination of Hydrogen Chloride in Flue Gas”memiliki rentang kerja 0,6 – 130 mg/Nm3. Disimpulkan bahwa metode terverifikasi sesuai tujuan dan laboratorium P3KLL mampu menunjukkan kompetensinya dalam menerapkan metode pengujian Hcl tersebut.
id IOS3429.--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-3088
institution Kementerian Lingkungan Hidup dan Kehutanan Republik Indonesia
institution_id 475
institution_type library:special
library
library Perpustakaan Kementerian Lingkungan Hidup dan Kehutanan RI
library_id 121
collection Indonesian Journal of Forestry Research
repository_id 3429
subject_area Kehutanan
Lingkungan
Pertanian
city BOGOR
province JAWA BARAT
repoId IOS3429
first_indexed 2017-08-20T01:13:09Z
last_indexed 2017-10-20T00:06:29Z
recordtype dc
_version_ 1764501242175815680
score 17.538404