PENENTUAN BATAS DETEKSI METODE (METHOD DETECTION LEVEL) DAN BATAS KUANTIFIKASI (LIMIT OF QUANTITATION) PENGUJIAN SULFIDA DALAM AIR DAN AIR LIMBAH DENGAN BIRU METILEN SECARA SPEKTROFOTOMETRI
Main Author: | hadi, Anwar |
---|---|
Format: | Article info eJournal |
Bahasa: | eng |
Terbitan: |
Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)
, 2010
|
Subjects: | |
Online Access: |
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495 http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495/1348 |
ctrlnum |
--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1495 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">PENENTUAN BATAS DETEKSI METODE (METHOD DETECTION LEVEL) DAN BATAS KUANTIFIKASI (LIMIT OF QUANTITATION) PENGUJIAN SULFIDA DALAM AIR DAN AIR LIMBAH DENGAN BIRU METILEN SECARA SPEKTROFOTOMETRI</title><creator>hadi, Anwar</creator><subject lang="en-US">Sulfida, batas deteksi metode, biru metilen dan spektrofotometri</subject><description lang="en-US">Batas deteksi metode didefinisikan sebagai konsentrasi analit yang ditentukan sesuai tahapan metode pengujian secara menyeluruh sehingga menghasilkan signal dengan probabilitas 99% bahwa signal tersebut berbeda dengan blanko. Batas deteksi metode dapat diperoleh ketika dilakukan oleh analis yang kompeten dengan menggunakan peralatan terkalibrasi pada keadaan yang dirancang sedemikian rupa sehingga berbeda dengan kegiatan pengujian rutin. Sedangkan batas kuentifikasi adalah konsentrasi analit yang menghasilkan signal lebih besar dari blanko pada kondisi kegiatan rutin laboratorium. Penentuan MDL untuk sulfide secara biru metilen dengan spektrofotometri sesuai APHA edisi 21 tahun 2005, 4500-S2-D adalah 0,01 mg/L dan LoQ 0,02 mg/L. Dengan %RSD = 10,5%, rerata %R = 95% dan MDL < kadar spike < 10 MDL = 0,01 < 0,02 < 0,1 maka MDL dan LoQ dapat diterima sesuai persyaratan US-EPA</description><publisher lang="en-US">Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL)</publisher><contributor lang="en-US"/><date>2010-06-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>Other:</type><identifier>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495</identifier><identifier>10.20886/jklh.2010.4.2.70-80</identifier><source lang="en-US">Jurnal Ecolab; Vol 4, No 2 (2010): Jurnal Ecolab; 70-80</source><source>2502-8812</source><source>1978-5860</source><language>eng</language><relation>http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495/1348</relation><rights lang="en-US">Copyright (c) 2016 Jurnal Ecolab</rights><rights lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</rights><recordID>--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1495</recordID></dc>
|
language |
eng |
format |
Journal:Article Journal Other:info:eu-repo/semantics/publishedVersion Other Other: Journal:eJournal |
author |
hadi, Anwar |
title |
PENENTUAN BATAS DETEKSI METODE (METHOD DETECTION LEVEL) DAN BATAS KUANTIFIKASI (LIMIT OF QUANTITATION) PENGUJIAN SULFIDA DALAM AIR DAN AIR LIMBAH DENGAN BIRU METILEN SECARA SPEKTROFOTOMETRI |
publisher |
Pusat Penelitian dan Pengembangan Kualitas dan Laboratorium Lingkungan (P3KLL) |
publishDate |
2010 |
topic |
Sulfida batas deteksi metode biru metilen dan spektrofotometri |
url |
http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495 http://ejournal.forda-mof.org/ejournal-litbang/index.php/JKLH/article/view/1495/1348 |
contents |
Batas deteksi metode didefinisikan sebagai konsentrasi analit yang ditentukan sesuai tahapan metode pengujian secara menyeluruh sehingga menghasilkan signal dengan probabilitas 99% bahwa signal tersebut berbeda dengan blanko. Batas deteksi metode dapat diperoleh ketika dilakukan oleh analis yang kompeten dengan menggunakan peralatan terkalibrasi pada keadaan yang dirancang sedemikian rupa sehingga berbeda dengan kegiatan pengujian rutin. Sedangkan batas kuentifikasi adalah konsentrasi analit yang menghasilkan signal lebih besar dari blanko pada kondisi kegiatan rutin laboratorium. Penentuan MDL untuk sulfide secara biru metilen dengan spektrofotometri sesuai APHA edisi 21 tahun 2005, 4500-S2-D adalah 0,01 mg/L dan LoQ 0,02 mg/L. Dengan %RSD = 10,5%, rerata %R = 95% dan MDL < kadar spike < 10 MDL = 0,01 < 0,02 < 0,1 maka MDL dan LoQ dapat diterima sesuai persyaratan US-EPA |
id |
IOS3429.--ejournal.forda-mof.org-ejournal-litbang-index.php-index-oai:article-1495 |
institution |
Kementerian Lingkungan Hidup dan Kehutanan Republik Indonesia |
institution_id |
475 |
institution_type |
library:special library |
library |
Perpustakaan Kementerian Lingkungan Hidup dan Kehutanan RI |
library_id |
121 |
collection |
Indonesian Journal of Forestry Research |
repository_id |
3429 |
subject_area |
Kehutanan Lingkungan Pertanian |
city |
BOGOR |
province |
JAWA BARAT |
repoId |
IOS3429 |
first_indexed |
2016-09-28T01:15:49Z |
last_indexed |
2016-09-28T01:15:49Z |
recordtype |
dc |
_version_ |
1764501241339052032 |
score |
17.538404 |