OPTIMASI DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS HIDROKUINON DALAM KRIM

Main Author: MUHAMAD HIDAYATULLAH CHOIR, 051211133052
Format: Thesis NonPeerReviewed Book
Bahasa: ind
Terbitan: , 2016
Subjects:
Online Access: http://repository.unair.ac.id/56100/1/FF.%20KF.%2009-16%20Cho%20o%20abstrak.pdf
http://repository.unair.ac.id/56100/2/FF.%20KF.%2009-16%20Cho%20o.pdf
http://repository.unair.ac.id/56100/
http://lib.unair.ac.id
Daftar Isi:
  • OPTIMIZATION AND VALIDATION OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE ANALYSIS HYDROQUINONE IN CREAM Hydroquinone (HQ) is used for threatment of hyperpigmented condition and also one of the active ingredients used in cosmetics. The objective of the present study was to optimize and validate the high performance liquid chromatography method for the analysis of a hidrqoquinone in cream. Chromatographic separation was achieved on Microbundapak C18 (3.9 x 300) 10 μm 125 A column and the mobile phase was a mixture methanol : water (40 : 60). The retention time for hydroquinone was 3.92 min, at flow rate of 0.8 mL/min. The UV detector was set 289 nm. The method was validated for specificity, linearity, accuracy, precision, limits of detection, and limits of quantification. The method was proved to be selective. Linearity showed linear respone (r = 0.9998) while correlation coeffecient of the function (Vxo) was 0.98% over the range of concentration used (between 5 mg L-1 to 35 mg L-1). Accuracy of method was in range of accepted limits (97% - 103%), recovery was found to be in the average of 101.78%, while the precision was 1.25%. The detection limit is 0.06 ppm and the quantification limit is 0.18 ppm. The proposed method was successfully applied for the analysis of hydroquinone in cream Keyword : OPTIMIZATION AND VALIDATION OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE ANALYSIS HYDROQUINONE IN CREAM Hydroquinone (HQ) is used for threatment of hyperpigmented condition and also one of the active ingredients used in cosmetics. The objective of the present study was to optimize and validate the high performance liquid chromatography method for the analysis of a hidrqoquinone in cream. Chromatographic separation was achieved on Microbundapak C18 (3.9 x 300) 10 μm 125 A column and the mobile phase was a mixture methanol : water (40 : 60). The retention time for hydroquinone was 3.92 min, at flow rate of 0.8 mL/min. The UV detector was set 289 nm. The method was validated for specificity, linearity, accuracy, precision, limits of detection, and limits of quantification. The method was proved to be selective. Linearity showed linear respone (r = 0.9998) while correlation coeffecient of the function (Vxo) was 0.98% over the range of concentration used (between 5 mg L-1 to 35 mg L-1). Accuracy of method was in range of accepted limits (97% - 103%), recovery was found to be in the average of 101.78%, while the precision was 1.25%. The detection limit is 0.06 ppm and the quantification limit is 0.18 ppm. The proposed method was successfully applied for the analysis of hydroquinone in cream Keyword : HPLC, Hydroquinone, Validation Method