PENGUKURAN RESOLUSI RUANG/SPASIAL TOMOGRAFI ULTRASONIK MELALUI PENGUKURAN FUNGSI SEBAR GARIS ATAU LINE SPREAD FUNCTION (LSF)

Main Authors: , Ego Srivajawaty Sinaga, , Prof. Kusminarto
Format: Thesis NonPeerReviewed
Terbitan: [Yogyakarta] : Universitas Gadjah Mada , 2011
Subjects:
ETD
Online Access: https://repository.ugm.ac.id/90880/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=52728
ctrlnum 90880
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>https://repository.ugm.ac.id/90880/</relation><title>PENGUKURAN RESOLUSI RUANG/SPASIAL TOMOGRAFI ULTRASONIK MELALUI PENGUKURAN FUNGSI SEBAR GARIS ATAU LINE SPREAD FUNCTION (LSF)</title><creator>, Ego Srivajawaty Sinaga</creator><creator>, Prof. Kusminarto</creator><subject>ETD</subject><description>Measurement of Spatial Resolution of Ultrasonic Tomography has been done. The objective of this research was to measure the Spatial Resolution of Ultrasonic Tomography by measuring the line spread function (LSF). A new ultrasonic Tomography System has been build in the early step to determine the possibility for further development into the actual facility Ultrasonic Tomography. This study uses a cylindrical object made of sand and cement with a volume ratio of 1:3 with a cube inside made of cement, gypsum and sand in the volume ratio of 1:4:2. The diameter of the cylinder is (11.20&#xEF;&#xFFFD;&#xB1; 0.01) mm, cube length and wide is (3.80&#xEF;&#xFFFD;&#xB1; 0.01) mm and (5.80 &#xEF;&#xFFFD;&#xB1; 0.01) mm, respectively. This system uses the data resolution (Projection x Ray-sum) of 200 x 127 with an increament of projection angles of 0.90. Images obtained were analyzed using excel program. Moreover, the MATLAB program R2007B used in the graph fitting process. The results obtained for spatial resolution measurements manually is 0.489 mm or about 5 pixels and the spatial resolution results in experiments ranged in value of (0.094&#xEF;&#xFFFD;&#xB1; 0.001) mm until (0.943 &#xEF;&#xFFFD;&#xB1; 0.001) mm or about 1 pixels until 12 pixels.</description><publisher>[Yogyakarta] : Universitas Gadjah Mada</publisher><date>2011</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><identifier> , Ego Srivajawaty Sinaga and , Prof. Kusminarto (2011) PENGUKURAN RESOLUSI RUANG/SPASIAL TOMOGRAFI ULTRASONIK MELALUI PENGUKURAN FUNGSI SEBAR GARIS ATAU LINE SPREAD FUNCTION (LSF). UNSPECIFIED thesis, UNSPECIFIED. </identifier><relation>http://etd.ugm.ac.id/index.php?mod=penelitian_detail&amp;sub=PenelitianDetail&amp;act=view&amp;typ=html&amp;buku_id=52728</relation><recordID>90880</recordID></dc>
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
author , Ego Srivajawaty Sinaga
, Prof. Kusminarto
title PENGUKURAN RESOLUSI RUANG/SPASIAL TOMOGRAFI ULTRASONIK MELALUI PENGUKURAN FUNGSI SEBAR GARIS ATAU LINE SPREAD FUNCTION (LSF)
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2011
topic ETD
url https://repository.ugm.ac.id/90880/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=52728
contents Measurement of Spatial Resolution of Ultrasonic Tomography has been done. The objective of this research was to measure the Spatial Resolution of Ultrasonic Tomography by measuring the line spread function (LSF). A new ultrasonic Tomography System has been build in the early step to determine the possibility for further development into the actual facility Ultrasonic Tomography. This study uses a cylindrical object made of sand and cement with a volume ratio of 1:3 with a cube inside made of cement, gypsum and sand in the volume ratio of 1:4:2. The diameter of the cylinder is (11.20� 0.01) mm, cube length and wide is (3.80� 0.01) mm and (5.80 � 0.01) mm, respectively. This system uses the data resolution (Projection x Ray-sum) of 200 x 127 with an increament of projection angles of 0.90. Images obtained were analyzed using excel program. Moreover, the MATLAB program R2007B used in the graph fitting process. The results obtained for spatial resolution measurements manually is 0.489 mm or about 5 pixels and the spatial resolution results in experiments ranged in value of (0.094� 0.001) mm until (0.943 � 0.001) mm or about 1 pixels until 12 pixels.
id IOS2744.90880
institution Universitas Gadjah Mada
institution_id 19
institution_type library:university
library
library Perpustakaan Pusat Universitas Gadjah Mada
library_id 488
collection UGM Repository
repository_id 2744
subject_area Karya Umum
city SLEMAN
province DAERAH ISTIMEWA YOGYAKARTA
repoId IOS2744
first_indexed 2016-09-14T18:27:03Z
last_indexed 2016-09-22T21:40:57Z
recordtype dc
_version_ 1765816213568487424
score 17.538404