Pengaruh Ketebalan Inner-Helical Fin Terhadap Charcteristic of Performance pada Head Exchanger
Main Authors: | Usman, Ishak, Wahyudi, Slamet, Argo, Bambang Dwi |
---|---|
Format: | Article info application/pdf eJournal |
Bahasa: | eng |
Terbitan: |
Jurusan Teknik Mesin, Fakultas Teknik, Universitas Brawijaya
, 2012
|
Online Access: |
https://rekayasamesin.ub.ac.id/index.php/rm/article/view/119 https://rekayasamesin.ub.ac.id/index.php/rm/article/view/119/109 |
Daftar Isi:
- Effect of inner-helical fin on the rate of heat transfer and flow friction factor in a double pipe heat exchanger (double tube heat exchanger) to make a split and disrupt the flow pattern of a streamlined flow of the fluid flowing in the pipe section in the (inner tube) that cause turbulence (molecule-molecule level of randomness good fluid) that can increase the heat transfer rate in the the pipe . Inner-helical fin has a varied thickness of 1 mm, 22 mm and 3 mm are mounted on the pipe where the inside diameter of the inner-helical fin attached to the wall in the inner pipe. Hot water discharge on the inner pipe ditelitil ranging from 400 to 900 liters / h with interval increase in 100 liter / hour and the volumetric flow rate of cold water on the outer tube (outertube) is kept constant 900 liters / hour. The test results of each inner-helical fin thickness compared with the test results without the inner-helical fin (plain tube) and obtained the overall heat transfer rate has increased 60 to 65% of the plain tube, heat exchanger effectiveness of58.56 to 63, 64% and friction factor of 63.13 to 63.51 of the plain tube.Keywords : Inner-helical fin, Heat exchanger, rate of heat transfer, friction factor