Perancangan prototipe light curing unit-light emitting diode (LCU-LED) dengan metode pulse width modulation (PWM) = Prototype design of light curing unit-light emitting diode (LCU-LED) using pulse width modulation (PWM) method
Format: | Masters Bachelors |
---|---|
Terbitan: |
Program Pascasarjana Universitas Indonesia
, 2015
|
Subjects: | |
Online Access: |
http://lib.ui.ac.id/file?file=digital/2016-3/20404357-T-Abdul Rachman Firdaus.pdf |
Daftar Isi:
- [Pemakaian LCU dengan irradiansi tinggi secara medis berpotensi merusak jaringan pulpa gigi akibat kenaikan suhu yang ditimbulkan. Tujuan penelitian ini adalah memperoleh prototipe LCU menggunakan High Power LED dengan 3 mode Pulse Width Modulation (PWM) untuk mengontrol sinar irradiansi sinar output pada mode 1 dengan irradiansi 800 mW/Cm2, mode 2 dengan irradiansi 900 mW/Cm2, mode 3 dengan irradiansi 1.000 mW/Cm2 yang berdurasi 5 detik, 10 detik dan 20 detik dan suhu sinar output ≤ 37 °C. Lampu yang digunakan LED biru high power komersial Model LZ4-00DB10 sebagai sumber sinar. Pengukuran irradiansi dan suhu dengan menggunakan LED Radiometer dan Thermocouple. Pada penelitian ini dihasilkan Prototipe LCU LED dengan metode kombinasi Pulse Width Modulation pada Mode 3 irradiansi 999 ± 3,16 mW/cm2 dan suhu sinar output 38,76 °C dengan durasi waktu penyinaran 20 detik. Pengaturan kombinasi PWM perlu disempurnakan lagi agar irradiansi diatas 1000 mW/cm2 dapat tercapai, sedangkan suhu sinar output LCU LED dapat terkendali tidak melebihi ≤ 37 °C., LCU with high irradiance medically potentially damage the dental pulp tissue due to the temperature rise caused objective of this study is to obtain a prototype LCU using High Power LED with 3 modes Pulse Width Modulation (PWM) to control the output light beam irradiance in mode 1 with irradiance of 800 mW / cm2, mode 2 with irradiance of 900 mW / cm2, mode 3 with irradiance of 1,000 mW / cm2 which lasts 5 seconds, 10 seconds and 20 seconds and the temperature of the output beam ≤ 37 ° C. Commercial high power blue LED as a light source LZ4- 00DB10 model. Irradiance and temperature measurement using the LED Radiometer and Thermocouple. In this study produced prototype LED LCU with a combination method Mode Pulse Width Modulation at 999 ± 3 irradiance of 3.16 mW / cm2 and a temperature of 38.76 ° C output beam with a duration of 20 seconds exposure time. PWM combination settings need to be revised so that the irradiance above 1000 mW / cm2 can be achieved, while the temperature of the output beam can be controlled LED LCU not ≤ 37 ° C.]