Trace element requirements for stable food waste digestion at elevated ammonia concentrations

Main Authors: Banks, Charles, Zhang, Yue, Jiang, Ying, Heaven, Sonia
Format: Article
Bahasa: eng
Terbitan: , 2012
Subjects:
Online Access: https://zenodo.org/record/983
Daftar Isi:
  • The work investigated why anaerobic digesters treating food waste and operating at high ammonia concentrations suffer from propionic acid accumulation which may result in process failure. The results showed deficiency of selenium, essential for both propionate oxidation and syntrophic hydrogenotrophic methanogenesis, leads to this while supplementation allows operation at substantially higher organic loading rates (OLR). At high loadings cobalt also becomes limiting, due to its role either in acetate oxidation in a reverse Wood-Ljungdahl pathway or in hydrogenotrophic methanogenesis. Population structure analysis using fluorescent in-situ hybridisation showed only hydrogenotrophic methanogens. Critical Se and Co concentrations were established as 0.16 and 0.22 mg kg-1 fresh matter feed at moderate loading. At this dosage the OLR could be raised to 5 g VS l-1 day-1 giving specific and volumetric biogas productions of 0.75 m3 kg-1 VSadded and 3.75 STP m3 m-3 day-1, representing a significant increase in process performance and operational stability.
  • This is a revised personal version of the text of the final journal article, which is made available for scholarly purposes only, in accordance with the journal's author permissions.