AAS Determination of Zinc after Separation with Liquid Chelating Exchanger and its Application to the Ganga River Water

Main Authors: SHUVENDU S. BHATTACHARYYA, ARABINDA K. DAS
Format: Article Journal
Bahasa: eng
Terbitan: , 1988
Subjects:
Online Access: https://zenodo.org/record/6123236
Daftar Isi:
  • Department of Chemistry, University of Burdwan, Burdwan-713 104 Manuscript received 7 January 1987, revised 17 July 1987, accepted 3 February 1988 FLAME and flameless atomic absorption spectra-photometric (AAS) determination of zinc has been described by several authors1-5. In most of the cases, different chelating agents have been used followed by extraction in suitable solvents. Solvent extraction behaviour of zinc with liquid ion-exchan­gers has also been studieds6,7. The present commu­nication reports the determination of zinc by AAS after its extraction with a new β-diketo liquid chelating exchanger8 (RCOCH2COCH3) in chloro­form as diluent. The effects of different variables have been investigated. The method has been applied successfully in the determination of zinc in the Ganga river water.