The excellent biocompatibility and negligible immune response towards the Titanium heterometallic MOF MUV-10
Main Authors: | Isabel Abánades Lázaro, Jose M Rodrigo-Muñoz,, Beatriz S Sastre, María Romero-Ángel, Carlos Martí-Gastaldo, Victoria del Pozo |
---|---|
Format: | Article Journal |
Terbitan: |
, 2021
|
Subjects: | |
Online Access: |
https://zenodo.org/record/5109496 |
Daftar Isi:
- The Ti-Ca heterometallic MOF MUV-10 has good dispersibility in phosphate buffer and low phosphate-induced degradation in comparison to other MOF systems. It induces no cytotoxicity towards cells of the immune system and no immune response, making it an attractive candidate for biomedical applications and accounting for its safe use for other applications.