Analysis of the energy performance of a ground source heat pump system after five years of operation

Main Authors: Montagud, C., Corberan, J., Montero, A., UrchueguĂ­a, J.
Format: Article Journal
Bahasa: eng
Terbitan: , 2011
Subjects:
Online Access: https://zenodo.org/record/1007
ctrlnum 1007
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><creator>Montagud, C.</creator><creator>Corberan, J.</creator><creator>Montero, A.</creator><creator>Urchuegu&#xED;a, J.</creator><date>2011-10-01</date><description>GeoCool plant was the result of a EU project whose main purpose was to adapt ground coupled heat pump technology to cooling dominated areas. The execution of this experimental plant was completed at the end of year 2004, starting on February 2005 the regular operation of the air conditioning system. Since then, GeoCool facility has been monitored by a network of sensors characterizing its most relevant parameters. Several aspects of the performance and behaviour of the system during its first operational year were presented on a previous paper. This paper presents the energy performance measurements of GeoCool ground coupled heat pump system acquired during five years of operation as well as the evolution of the return water temperature from the ground as a representative of the ground temperature. The analysis of the experimental results shows that the system energy performance is maintained through the years with no appreciable impact on ground thermal response.</description><identifier>https://zenodo.org/record/1007</identifier><identifier>10.1016/j.enbuild.2011.09.036</identifier><identifier>oai:openaire.cern.ch:1007</identifier><language>eng</language><relation>info:eu-repo/grantAgreement/EC/FP7/218895/</relation><relation>url:https://zenodo.org/communities/ecfunded</relation><relation>url:https://zenodo.org/communities/zenodo</relation><rights>info:eu-repo/semantics/closedAccess</rights><source>Energy and Buildings 43(12) 3618&#x2013;3626 (2011)</source><subject>Energy efficiency</subject><subject>Ground coupled heat pump</subject><subject>Heating and cooling systems</subject><title>Analysis of the energy performance of a ground source heat pump system after five years of operation</title><type>Journal:Article</type><type>Journal:Article</type><recordID>1007</recordID></dc>
language eng
format Journal:Article
Journal
Journal:Journal
author Montagud, C.
Corberan, J.
Montero, A.
UrchueguĂ­a, J.
title Analysis of the energy performance of a ground source heat pump system after five years of operation
publishDate 2011
topic Energy efficiency
Ground coupled heat pump
Heating and cooling systems
url https://zenodo.org/record/1007
contents GeoCool plant was the result of a EU project whose main purpose was to adapt ground coupled heat pump technology to cooling dominated areas. The execution of this experimental plant was completed at the end of year 2004, starting on February 2005 the regular operation of the air conditioning system. Since then, GeoCool facility has been monitored by a network of sensors characterizing its most relevant parameters. Several aspects of the performance and behaviour of the system during its first operational year were presented on a previous paper. This paper presents the energy performance measurements of GeoCool ground coupled heat pump system acquired during five years of operation as well as the evolution of the return water temperature from the ground as a representative of the ground temperature. The analysis of the experimental results shows that the system energy performance is maintained through the years with no appreciable impact on ground thermal response.
id IOS16997.1007
institution ZAIN Publications
institution_id 7213
institution_type library:special
library
library Cognizance Journal of Multidisciplinary Studies
library_id 5267
collection Cognizance Journal of Multidisciplinary Studies
repository_id 16997
subject_area Multidisciplinary
city Stockholm
province INTERNASIONAL
shared_to_ipusnas_str 1
repoId IOS16997
first_indexed 2022-06-06T05:52:03Z
last_indexed 2022-06-06T05:52:03Z
recordtype dc
_version_ 1734906750878875648
score 17.538404