ANALISA NILAI ARUS SETTING DAN WAKTU KERJA OVER CURRENT RELAY (OCR) TERHADAP GANGGUAN HUBUNG SINGKAT DI PENYULANG TRANSFORMATOR 7,5 MVA/13,8 kV PT. PUPUK SRIWIDJAJA PALEMBANG
Main Author: | ARIANDI, BOBBY REXEN |
---|---|
Format: | Thesis NonPeerReviewed Book |
Bahasa: | eng |
Terbitan: |
, 2019
|
Subjects: | |
Online Access: |
http://eprints.polsri.ac.id/8151/1/COVER.pdf http://eprints.polsri.ac.id/8151/2/BAB%20I-dikonversi.pdf http://eprints.polsri.ac.id/8151/3/BAB%20II-dikonversi.pdf http://eprints.polsri.ac.id/8151/4/BAB_III.PDF http://eprints.polsri.ac.id/8151/5/BAB_IV.PDF http://eprints.polsri.ac.id/8151/6/BAB_V.PDF http://eprints.polsri.ac.id/8151/7/DAFTAR_PUSTAKA_FIX.PDF http://eprints.polsri.ac.id/8151/ |
ctrlnum |
8151 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/8151/</relation><title>ANALISA NILAI ARUS SETTING DAN WAKTU KERJA OVER CURRENT RELAY (OCR) TERHADAP GANGGUAN HUBUNG SINGKAT DI PENYULANG TRANSFORMATOR 7,5 MVA/13,8 kV PT. PUPUK SRIWIDJAJA PALEMBANG</title><creator>ARIANDI, BOBBY REXEN</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>Relay arus lebih atau lebih dikenal OCR (Over Current Relay) merupakan peralatan yang menysinyalir adanya arus lebih yang disebabkan oleh adanya gangguan hubung singkat atau over load yang dapat merusak peralatan sistem tenaga yang berbeda dalam wilayah proteksinya.Besarnya gangguan hubung singkatberbanding terbalik dengan jarak baik itu 3 fasa dan 2 fasa,karena semakin jauh jarak gangguan hubung singkat maka semakin kecil gangguan hubung singkat yang terjadi pada titik gangguan masing masing penyulang.Dan semakin dekat jarak gangguan singkat maka semakin kecil gangguan hubung singkat yang didapat.Besar nilai tms berdasarkan data dilapangan terlalu besar sehingga menyebabkan waktu kerja OCR menjadi lama.Sedangkan jika dibandingkan dengan nilai tms 0,1 maka waktu kerja OCR akan menjadi cepat dan efisien.Ditinjau dari jarak bahwasanya semakin dekat jarak titik gangguan hubung singkat maka semakin cepat waktu kerja OCR dan sebaliknya.</description><date>2019-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/1/COVER.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/2/BAB%20I-dikonversi.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/3/BAB%20II-dikonversi.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/4/BAB_III.PDF</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/5/BAB_IV.PDF</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/6/BAB_V.PDF</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/8151/7/DAFTAR_PUSTAKA_FIX.PDF</identifier><identifier> ARIANDI, BOBBY REXEN (2019) ANALISA NILAI ARUS SETTING DAN WAKTU KERJA OVER CURRENT RELAY (OCR) TERHADAP GANGGUAN HUBUNG SINGKAT DI PENYULANG TRANSFORMATOR 7,5 MVA/13,8 kV PT. PUPUK SRIWIDJAJA PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>8151</recordID></dc>
|
language |
eng |
format |
Thesis:Thesis Thesis PeerReview:NonPeerReviewed PeerReview Book:Book Book |
author |
ARIANDI, BOBBY REXEN |
title |
ANALISA NILAI ARUS SETTING DAN WAKTU KERJA OVER CURRENT RELAY (OCR) TERHADAP GANGGUAN HUBUNG SINGKAT DI PENYULANG TRANSFORMATOR 7,5 MVA/13,8 kV PT. PUPUK SRIWIDJAJA PALEMBANG |
publishDate |
2019 |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
url |
http://eprints.polsri.ac.id/8151/1/COVER.pdf http://eprints.polsri.ac.id/8151/2/BAB%20I-dikonversi.pdf http://eprints.polsri.ac.id/8151/3/BAB%20II-dikonversi.pdf http://eprints.polsri.ac.id/8151/4/BAB_III.PDF http://eprints.polsri.ac.id/8151/5/BAB_IV.PDF http://eprints.polsri.ac.id/8151/6/BAB_V.PDF http://eprints.polsri.ac.id/8151/7/DAFTAR_PUSTAKA_FIX.PDF http://eprints.polsri.ac.id/8151/ |
contents |
Relay arus lebih atau lebih dikenal OCR (Over Current Relay) merupakan peralatan yang menysinyalir adanya arus lebih yang disebabkan oleh adanya gangguan hubung singkat atau over load yang dapat merusak peralatan sistem tenaga yang berbeda dalam wilayah proteksinya.Besarnya gangguan hubung singkatberbanding terbalik dengan jarak baik itu 3 fasa dan 2 fasa,karena semakin jauh jarak gangguan hubung singkat maka semakin kecil gangguan hubung singkat yang terjadi pada titik gangguan masing masing penyulang.Dan semakin dekat jarak gangguan singkat maka semakin kecil gangguan hubung singkat yang didapat.Besar nilai tms berdasarkan data dilapangan terlalu besar sehingga menyebabkan waktu kerja OCR menjadi lama.Sedangkan jika dibandingkan dengan nilai tms 0,1 maka waktu kerja OCR akan menjadi cepat dan efisien.Ditinjau dari jarak bahwasanya semakin dekat jarak titik gangguan hubung singkat maka semakin cepat waktu kerja OCR dan sebaliknya. |
id |
IOS15200.8151 |
institution |
Politeknik Negeri Sriwijaya |
institution_id |
186 |
institution_type |
library:university library |
library |
Perpustakaan Politeknik Negeri Sriwijaya |
library_id |
333 |
collection |
Perpustakaan Politeknik Negeri Sriwijaya |
repository_id |
15200 |
city |
KOTA PALEMBANG |
province |
SUMATERA SELATAN |
repoId |
IOS15200 |
first_indexed |
2021-08-25T09:33:54Z |
last_indexed |
2021-08-25T09:33:54Z |
recordtype |
dc |
_version_ |
1709058339223109632 |
score |
17.538404 |