ctrlnum 4437
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/4437/</relation><title>EVALUASI PENTANAHAN PERALATAN TRANSFORMATOR&#xD; DAYA 30 MVA PADA GARDU INDUK BUKIT SIGUNTANG&#xD; PT. PLN (PERSERO) PALEMBANG</title><creator>LESTARI, ELSA INDAH</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>With the evaluation of the grounding value of the equipment that has been done, the grounding of the measurement equipment of the electrode resistance value of the grounding rod of equipment at the GI Bukit Siguntang power transformer is 00,276 ohms, while the calculation is obtained with the value of 0.073 ohm electrode resistance. The result has a difference of 0.203 ohm. While actual Touch Voltage is obtained at 49,91 V, which means that the actual touch voltage is below the allowable touch tension standard of 164 V, and the actual step voltage is 22,40 V, where the actual step value is also below the standard allowable step voltage Of 99,59 V so that the resistance value of the equipment has met the existing requirements, namely &#x2264; 5 &#x3A9; according to PUIL and &#x2264; 1 &#x3A9; so that the ground equipment on the power transformer in the substation PT. PLN (Persero) Bukit Siguntang already meet the provisions and still not harm human.</description><date>2017-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/1/File%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/2/File%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/3/File%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/4/File%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/5/File%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/6/File%20VI.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4437/7/File%20VII.pdf</identifier><identifier> LESTARI, ELSA INDAH (2017) EVALUASI PENTANAHAN PERALATAN TRANSFORMATOR DAYA 30 MVA PADA GARDU INDUK BUKIT SIGUNTANG PT. PLN (PERSERO) PALEMBANG. Other thesis, POLITEKNIK NEGERI SRIWIJAYA. </identifier><recordID>4437</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author LESTARI, ELSA INDAH
title EVALUASI PENTANAHAN PERALATAN TRANSFORMATOR DAYA 30 MVA PADA GARDU INDUK BUKIT SIGUNTANG PT. PLN (PERSERO) PALEMBANG
publishDate 2017
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/4437/1/File%20I.pdf
http://eprints.polsri.ac.id/4437/2/File%20II.pdf
http://eprints.polsri.ac.id/4437/3/File%20III.pdf
http://eprints.polsri.ac.id/4437/4/File%20IV.pdf
http://eprints.polsri.ac.id/4437/5/File%20V.pdf
http://eprints.polsri.ac.id/4437/6/File%20VI.pdf
http://eprints.polsri.ac.id/4437/7/File%20VII.pdf
http://eprints.polsri.ac.id/4437/
contents With the evaluation of the grounding value of the equipment that has been done, the grounding of the measurement equipment of the electrode resistance value of the grounding rod of equipment at the GI Bukit Siguntang power transformer is 00,276 ohms, while the calculation is obtained with the value of 0.073 ohm electrode resistance. The result has a difference of 0.203 ohm. While actual Touch Voltage is obtained at 49,91 V, which means that the actual touch voltage is below the allowable touch tension standard of 164 V, and the actual step voltage is 22,40 V, where the actual step value is also below the standard allowable step voltage Of 99,59 V so that the resistance value of the equipment has met the existing requirements, namely ≤ 5 Ω according to PUIL and ≤ 1 Ω so that the ground equipment on the power transformer in the substation PT. PLN (Persero) Bukit Siguntang already meet the provisions and still not harm human.
id IOS15200.4437
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:31:36Z
last_indexed 2021-08-25T09:31:36Z
recordtype dc
_version_ 1709058371924000768
score 17.538404