ctrlnum 4435
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/4435/</relation><title>EVALUASI PEMERATAAN BEBAN TERHADAP GARDU DISTRIBUSI &#xD; U 020 PT.PLN (Persero) RAYON AMPERA PALEMBANG</title><creator>RIZKI, BAYU ICHWANUL</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>The baboon imbalance in the distribution transformer can cause neutral currents. The current in the transformer neutral conductor causes the loss of power in the distribution transformer. This final report investigates the unbalance of each phase load on the distribution transformer. The investigation is carried out with current calculations on the neutral carrier. To reduce the current in the neutral conductor the load equalization from phase one to another phase until the load on the pasa is balanced or close to balance. Calculation is done through transformer U 020 at PT.PLN (Persero) rayon ampera palembang. The calculation results show that if the equal load current is neutral and the power losses due to the imbalance of the transformer load are reduced. The neutral current from 37.01 A was reduced to 1.73 A and the power losses from 992.376702 W &#xD; were reduced to 2.17 W.</description><date>2017-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/1/COVER%2C%20DAFTAR%20ISI............pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4435/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> RIZKI, BAYU ICHWANUL (2017) EVALUASI PEMERATAAN BEBAN TERHADAP GARDU DISTRIBUSI U 020 PT.PLN (Persero) RAYON AMPERA PALEMBANG. Other thesis, POLITEKNIK NEGERI SRIWIJAYA. </identifier><recordID>4435</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author RIZKI, BAYU ICHWANUL
title EVALUASI PEMERATAAN BEBAN TERHADAP GARDU DISTRIBUSI U 020 PT.PLN (Persero) RAYON AMPERA PALEMBANG
publishDate 2017
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/4435/1/COVER%2C%20DAFTAR%20ISI............pdf
http://eprints.polsri.ac.id/4435/2/BAB%20I.pdf
http://eprints.polsri.ac.id/4435/3/BAB%20II.pdf
http://eprints.polsri.ac.id/4435/4/BAB%20III.pdf
http://eprints.polsri.ac.id/4435/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/4435/6/BAB%20V.pdf
http://eprints.polsri.ac.id/4435/7/DAFTAR%20PUSTAKA.pdf
http://eprints.polsri.ac.id/4435/
contents The baboon imbalance in the distribution transformer can cause neutral currents. The current in the transformer neutral conductor causes the loss of power in the distribution transformer. This final report investigates the unbalance of each phase load on the distribution transformer. The investigation is carried out with current calculations on the neutral carrier. To reduce the current in the neutral conductor the load equalization from phase one to another phase until the load on the pasa is balanced or close to balance. Calculation is done through transformer U 020 at PT.PLN (Persero) rayon ampera palembang. The calculation results show that if the equal load current is neutral and the power losses due to the imbalance of the transformer load are reduced. The neutral current from 37.01 A was reduced to 1.73 A and the power losses from 992.376702 W were reduced to 2.17 W.
id IOS15200.4435
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:31:36Z
last_indexed 2021-08-25T09:31:36Z
recordtype dc
_version_ 1709058371930292224
score 17.538404