ctrlnum 4433
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/4433/</relation><title>EVALUASI RELAY OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) PADA GI GANDUS MENGGUNAKAN SOFTWARE ETAP 12.6.0</title><creator>BIMANTARA, ROBBY</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>In electrical system there are always a protection system to anticipate unexpected circumstances when fault is occured in a system. This protection systems are necessary to separate a trouble part with a normal part to make sure that the system can operate as normally.Over current relay and ground fault relay are works by monitoring the amount of current that is contained in the conductor, when the amount of current is exceeds the adjusment of relay, and then relay will work to instructs Circuit Breaker to break distribution system. One of the trouble that cause an increases in electric current is short circuit fault that makes a current which flow on a conductor is exceeds maximum value of the conductor or electrical equipments. So that, the author is discuss setting of over current relay and ground fault relay and also to make a simulation of &#x201C;coordination over current relay and ground fault relay&#x201D; on ETAP 12.6.0 program. This program is purpose to design an electrical systemand simulate it. Is it in accordance with the actual setting</description><date>2017-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/1/File%201.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/2/File%202.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/3/File%203.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/4/File%204.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/5/File%205.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/6/File%206.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/4433/7/File%207.pdf</identifier><identifier> BIMANTARA, ROBBY (2017) EVALUASI RELAY OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) PADA GI GANDUS MENGGUNAKAN SOFTWARE ETAP 12.6.0. Other thesis, POLITEKNIK NEGERI SRIWIJAYA. </identifier><recordID>4433</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author BIMANTARA, ROBBY
title EVALUASI RELAY OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) PADA GI GANDUS MENGGUNAKAN SOFTWARE ETAP 12.6.0
publishDate 2017
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/4433/1/File%201.pdf
http://eprints.polsri.ac.id/4433/2/File%202.pdf
http://eprints.polsri.ac.id/4433/3/File%203.pdf
http://eprints.polsri.ac.id/4433/4/File%204.pdf
http://eprints.polsri.ac.id/4433/5/File%205.pdf
http://eprints.polsri.ac.id/4433/6/File%206.pdf
http://eprints.polsri.ac.id/4433/7/File%207.pdf
http://eprints.polsri.ac.id/4433/
contents In electrical system there are always a protection system to anticipate unexpected circumstances when fault is occured in a system. This protection systems are necessary to separate a trouble part with a normal part to make sure that the system can operate as normally.Over current relay and ground fault relay are works by monitoring the amount of current that is contained in the conductor, when the amount of current is exceeds the adjusment of relay, and then relay will work to instructs Circuit Breaker to break distribution system. One of the trouble that cause an increases in electric current is short circuit fault that makes a current which flow on a conductor is exceeds maximum value of the conductor or electrical equipments. So that, the author is discuss setting of over current relay and ground fault relay and also to make a simulation of “coordination over current relay and ground fault relay” on ETAP 12.6.0 program. This program is purpose to design an electrical systemand simulate it. Is it in accordance with the actual setting
id IOS15200.4433
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:31:36Z
last_indexed 2021-08-25T09:31:36Z
recordtype dc
_version_ 1709058371936583680
score 17.538404