ctrlnum 405
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/405/</relation><title>ANALISA BESAR KERUGIAN TEGANGAN PADA JARINGAN&#xD; DISTRIBUSI PRIMER 20 KV DI GARDU INDUK SEDUDUK PUTIH&#xD; PT.PLN (PERSERO) UPT PALEMBANG</title><creator>Alam Nurmansyah, Arasy</creator><subject>TJ Mechanical engineering and machinery</subject><description>In electric power distribution, usually there will be loss of voltage and&#xD; power on each channel, this is due to several factors that lead to job losses in the&#xD; channel, among other things: The amount of current flowing in the channel,&#xD; channel length, and channel impedance factor other. Voltage and power must be&#xD; at the limit, so that the voltage and the received power can still be used&#xD; effectively. To know the amount of loss then made an accurate analysis and&#xD; calculations so that the data generated precise and detailed. Voltage loss in the&#xD; value of each feeder in the substation White Seduduk happens to feeders Pigeon,&#xD; Magpie, and Kutilang at peak load is still below the standard PLN 5%, while for&#xD; feeder Swallow and Kutilang (peak night), where the feeder swallow at peak load&#xD; of 7.90% during the day and at night at 9.85, and a finch feeder in the evening&#xD; peak load of 5.57% which has exceeded the limits of the conditions set by PLN&#xD; 5% for the radial system, in accordance with SPLN 72: 1987.&#xD; Keywords: Voltage, Losses, Network Distribution, SPLN</description><date>2014-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/1/COVER.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/5/bab%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/6/bab%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/405/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> Alam Nurmansyah, Arasy (2014) ANALISA BESAR KERUGIAN TEGANGAN PADA JARINGAN DISTRIBUSI PRIMER 20 KV DI GARDU INDUK SEDUDUK PUTIH PT.PLN (PERSERO) UPT PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>405</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author Alam Nurmansyah, Arasy
title ANALISA BESAR KERUGIAN TEGANGAN PADA JARINGAN DISTRIBUSI PRIMER 20 KV DI GARDU INDUK SEDUDUK PUTIH PT.PLN (PERSERO) UPT PALEMBANG
publishDate 2014
topic TJ Mechanical engineering and machinery
url http://eprints.polsri.ac.id/405/1/COVER.pdf
http://eprints.polsri.ac.id/405/2/BAB%20I.pdf
http://eprints.polsri.ac.id/405/3/BAB%20II.pdf
http://eprints.polsri.ac.id/405/4/BAB%20III.pdf
http://eprints.polsri.ac.id/405/5/bab%20IV.pdf
http://eprints.polsri.ac.id/405/6/bab%20V.pdf
http://eprints.polsri.ac.id/405/7/DAFTAR%20PUSTAKA.pdf
http://eprints.polsri.ac.id/405/
contents In electric power distribution, usually there will be loss of voltage and power on each channel, this is due to several factors that lead to job losses in the channel, among other things: The amount of current flowing in the channel, channel length, and channel impedance factor other. Voltage and power must be at the limit, so that the voltage and the received power can still be used effectively. To know the amount of loss then made an accurate analysis and calculations so that the data generated precise and detailed. Voltage loss in the value of each feeder in the substation White Seduduk happens to feeders Pigeon, Magpie, and Kutilang at peak load is still below the standard PLN 5%, while for feeder Swallow and Kutilang (peak night), where the feeder swallow at peak load of 7.90% during the day and at night at 9.85, and a finch feeder in the evening peak load of 5.57% which has exceeded the limits of the conditions set by PLN 5% for the radial system, in accordance with SPLN 72: 1987. Keywords: Voltage, Losses, Network Distribution, SPLN
id IOS15200.405
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:27:47Z
last_indexed 2021-08-25T09:27:47Z
recordtype dc
_version_ 1709058410811490304
score 17.538404