ANALISA ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN MENENGAH 20 kV UNTUK MENENTUKAN KARAKTERSITIK RELAY ARUS LEBIH DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO)
Main Author: | Budiharjo, Satriyo |
---|---|
Format: | Thesis NonPeerReviewed Book |
Bahasa: | eng |
Terbitan: |
, 2014
|
Subjects: | |
Online Access: |
http://eprints.polsri.ac.id/384/1/COVER%20LENGKAP.pdf http://eprints.polsri.ac.id/384/2/BAB%20I.pdf http://eprints.polsri.ac.id/384/3/BAB%20II.pdf http://eprints.polsri.ac.id/384/4/BAB%20III.pdf http://eprints.polsri.ac.id/384/5/BAB%20IV.pdf http://eprints.polsri.ac.id/384/6/BAB%20V.pdf http://eprints.polsri.ac.id/384/7/DAFTAR%20PUSTAKA.pdf http://eprints.polsri.ac.id/384/ |
ctrlnum |
384 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/384/</relation><title>ANALISA ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN
MENENGAH 20 kV UNTUK MENENTUKAN KARAKTERSITIK
RELAY ARUS LEBIH DI GARDU INDUK TALANG KELAPA
PT. PLN (PERSERO)</title><creator>Budiharjo, Satriyo</creator><subject>TJ Mechanical engineering and machinery</subject><description>Gangguan hubung singkat dapat menyebabkan kerusakan pada jaringan
system tenaga listrik. Untuk mencapai keamanan yang lebih baik dalam
penyaluran daya serta peralatan yang terpasang pada gardu jaringan distribusi
primer, maka perlu dilakukan penyetingan atau penyetelan pengaman relay arus
lebih (over current relay).
Laporan akhir ini menyelidiki karakteristik relay arus lebih berdasarkan
hubung singkat pada jaringan tegangan menengah 20 kV dengan jarak dan area
yang berdeda serta penyetelan arus dan waktu pada relay arus lebih. Penyelidikan
dilakukan melalui studi kasus di Gardu Induk Talang Kelapa PT. PLN ( Persero ).
Hasil dari analisa yang didapat bahwa karakteristik relay arus lebih pada
jaringan tegangan menengah 20 kV menggunakan karakteristik relay standard
inverse ditinjau dari hasil perhitungan arus gangguan 3 fasa dan waktu penyetelan
relay yaitu pada 0 % dengan arus gangguan hubung singkat 3 fasa sebesar
11782,6 A dengan waktu penyetelan relay selama 0,26 detik, pada titik 25 %
dengan arus gangguan 3 fasa sebesar 3229 A dengan waktu penyetelan relay
selama 1 detik dan pada titik 50 % dengan arus gangguan hubung singkat tiga fasa
sebesar 1924,5 A dengan waktu penyetelan relay selama 10 detik.</description><date>2014-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/1/COVER%20LENGKAP.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/384/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> Budiharjo, Satriyo (2014) ANALISA ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN MENENGAH 20 kV UNTUK MENENTUKAN KARAKTERSITIK RELAY ARUS LEBIH DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO). Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>384</recordID></dc>
|
language |
eng |
format |
Thesis:Thesis Thesis PeerReview:NonPeerReviewed PeerReview Book:Book Book |
author |
Budiharjo, Satriyo |
title |
ANALISA ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN
MENENGAH 20 kV UNTUK MENENTUKAN KARAKTERSITIK
RELAY ARUS LEBIH DI GARDU INDUK TALANG KELAPA
PT. PLN (PERSERO) |
publishDate |
2014 |
topic |
TJ Mechanical engineering and machinery |
url |
http://eprints.polsri.ac.id/384/1/COVER%20LENGKAP.pdf http://eprints.polsri.ac.id/384/2/BAB%20I.pdf http://eprints.polsri.ac.id/384/3/BAB%20II.pdf http://eprints.polsri.ac.id/384/4/BAB%20III.pdf http://eprints.polsri.ac.id/384/5/BAB%20IV.pdf http://eprints.polsri.ac.id/384/6/BAB%20V.pdf http://eprints.polsri.ac.id/384/7/DAFTAR%20PUSTAKA.pdf http://eprints.polsri.ac.id/384/ |
contents |
Gangguan hubung singkat dapat menyebabkan kerusakan pada jaringan
system tenaga listrik. Untuk mencapai keamanan yang lebih baik dalam
penyaluran daya serta peralatan yang terpasang pada gardu jaringan distribusi
primer, maka perlu dilakukan penyetingan atau penyetelan pengaman relay arus
lebih (over current relay).
Laporan akhir ini menyelidiki karakteristik relay arus lebih berdasarkan
hubung singkat pada jaringan tegangan menengah 20 kV dengan jarak dan area
yang berdeda serta penyetelan arus dan waktu pada relay arus lebih. Penyelidikan
dilakukan melalui studi kasus di Gardu Induk Talang Kelapa PT. PLN ( Persero ).
Hasil dari analisa yang didapat bahwa karakteristik relay arus lebih pada
jaringan tegangan menengah 20 kV menggunakan karakteristik relay standard
inverse ditinjau dari hasil perhitungan arus gangguan 3 fasa dan waktu penyetelan
relay yaitu pada 0 % dengan arus gangguan hubung singkat 3 fasa sebesar
11782,6 A dengan waktu penyetelan relay selama 0,26 detik, pada titik 25 %
dengan arus gangguan 3 fasa sebesar 3229 A dengan waktu penyetelan relay
selama 1 detik dan pada titik 50 % dengan arus gangguan hubung singkat tiga fasa
sebesar 1924,5 A dengan waktu penyetelan relay selama 10 detik. |
id |
IOS15200.384 |
institution |
Politeknik Negeri Sriwijaya |
institution_id |
186 |
institution_type |
library:university library |
library |
Perpustakaan Politeknik Negeri Sriwijaya |
library_id |
333 |
collection |
Perpustakaan Politeknik Negeri Sriwijaya |
repository_id |
15200 |
city |
KOTA PALEMBANG |
province |
SUMATERA SELATAN |
repoId |
IOS15200 |
first_indexed |
2021-08-25T09:27:46Z |
last_indexed |
2021-08-25T09:27:46Z |
recordtype |
dc |
_version_ |
1709058411592679424 |
score |
17.538404 |