fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/3791/</relation><title>PERHITUNGAN RUGI-RUGI PADA SIMULASI SALURAN TRANSMISI 380 KV JARAK 300 KM DI LABORATORIUM TEKNIK LISTRIK POLITEKNIK NEGERI SRIWIJAYA</title><creator>HANDAYANI, MERRY</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>The final report is about the calculation of losses on the transmission line simulation in the laboratory of electrical engineering polytechnic sriwijaya. The data is collected on the no-load experiment, mixed loads experiment with a load R and L, mixed loads experiment with a load R, L, and C. In the experiment with no load the result of voltage loss is -18 V and the power loss 0 W because there is no value power active and power reactive in the no-load experiment. In the mixed loads experiment with a load R and L the result of voltage loss is 34 V and the result of power loss is 4 W. In the mixed loads experiment with a load R, L, and C the result of voltage loss is -11 V and the result of power loss is 8 W. The factors that cause the voltage loss and power loss are the resistance, inductive reactance, and capacitive reactance. In a transmission line of middle and upper value of the capacitive reactance should not be ignored. The value of capacitance along the line, very influences the voltage loss. In addition, other factors that cause the voltage loss and power loss are resistivity conductor, conductor area, the line length and the magnitude of the current flowing in the transmission line.</description><date>2016-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/1/FILE%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/2/FILE%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/3/FILE%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/4/FILE%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/5/FILE%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/6/FILE%20VI.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3791/7/FILE%20VII.pdf</identifier><identifier> HANDAYANI, MERRY (2016) PERHITUNGAN RUGI-RUGI PADA SIMULASI SALURAN TRANSMISI 380 KV JARAK 300 KM DI LABORATORIUM TEKNIK LISTRIK POLITEKNIK NEGERI SRIWIJAYA. Other thesis, POLITEKNIK NEGERI SRIWIJAYA. </identifier><recordID>3791</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author HANDAYANI, MERRY
title PERHITUNGAN RUGI-RUGI PADA SIMULASI SALURAN TRANSMISI 380 KV JARAK 300 KM DI LABORATORIUM TEKNIK LISTRIK POLITEKNIK NEGERI SRIWIJAYA
publishDate 2016
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/3791/1/FILE%20I.pdf
http://eprints.polsri.ac.id/3791/2/FILE%20II.pdf
http://eprints.polsri.ac.id/3791/3/FILE%20III.pdf
http://eprints.polsri.ac.id/3791/4/FILE%20IV.pdf
http://eprints.polsri.ac.id/3791/5/FILE%20V.pdf
http://eprints.polsri.ac.id/3791/6/FILE%20VI.pdf
http://eprints.polsri.ac.id/3791/7/FILE%20VII.pdf
http://eprints.polsri.ac.id/3791/
contents The final report is about the calculation of losses on the transmission line simulation in the laboratory of electrical engineering polytechnic sriwijaya. The data is collected on the no-load experiment, mixed loads experiment with a load R and L, mixed loads experiment with a load R, L, and C. In the experiment with no load the result of voltage loss is -18 V and the power loss 0 W because there is no value power active and power reactive in the no-load experiment. In the mixed loads experiment with a load R and L the result of voltage loss is 34 V and the result of power loss is 4 W. In the mixed loads experiment with a load R, L, and C the result of voltage loss is -11 V and the result of power loss is 8 W. The factors that cause the voltage loss and power loss are the resistance, inductive reactance, and capacitive reactance. In a transmission line of middle and upper value of the capacitive reactance should not be ignored. The value of capacitance along the line, very influences the voltage loss. In addition, other factors that cause the voltage loss and power loss are resistivity conductor, conductor area, the line length and the magnitude of the current flowing in the transmission line.
id IOS15200.3791
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:31:14Z
last_indexed 2021-08-25T09:31:14Z
recordtype dc
_version_ 1709058375319289856
score 17.538404