fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/361/</relation><title>ANALISA KETIDAKSEIMBANGAN BEBAN&#xD; PADA TRANSFORMATOR I. 974 PENYULANG PANDU&#xD; PT. PLN (PERSERO) RAYON SUKARAMI PALEMBANG</title><creator>INTAN YOLANDA, RIZKA</creator><subject>TJ Mechanical engineering and machinery</subject><description>RIZKA INTAN YOLANDA&#xD; 0611 3031 1452&#xD; MAJORING ELECTRICAL ENGINEERING&#xD; Unbalance Load on the each phase of distribution lines substation in the I.&#xD; 974 at PT. PLN (Persero) Rayon Sukaranmi to reduce neutral currents carried&#xD; the burden of load balancing. And results of measurements and calculations show&#xD; that the percentage of load imbalance each lines after the balancing the load is&#xD; reduced. In the majors B from 72% to 6,67%, majoring C from 77.67% to 6.33%,&#xD; majoring D from 72% to 6,67%,. Reduced the percentage of load imbalance with&#xD; the current flowing in the neutral conductor is also reduced. In I. 974 substation&#xD; measurement we cam see which phase that have unbalance load. Losses due to&#xD; the current in the neutral conductor of the transformer in the LWBP is 6,285 kW&#xD; and then balanced to LWBP is 0,079 kW. And WBP after balance is 26,091 kW&#xD; and then balanced to LWBP is 0,221 kW. So, the bigger unbalance load happen,&#xD; the losses cause by neutral conductor will be bigger.&#xD; Key Words : Unbalance Load, Neutral Current, Losses</description><date>2014-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/1/COVER%282%29.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/2/BAB1.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/3/BAB2.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/4/BAB3.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/5/BAB4.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/6/BAB5.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/7/DAFTAR%20PUSTAKA%282%29.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/361/8/lampiran.pdf</identifier><identifier> INTAN YOLANDA, RIZKA (2014) ANALISA KETIDAKSEIMBANGAN BEBAN PADA TRANSFORMATOR I. 974 PENYULANG PANDU PT. PLN (PERSERO) RAYON SUKARAMI PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>361</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author INTAN YOLANDA, RIZKA
title ANALISA KETIDAKSEIMBANGAN BEBAN PADA TRANSFORMATOR I. 974 PENYULANG PANDU PT. PLN (PERSERO) RAYON SUKARAMI PALEMBANG
publishDate 2014
topic TJ Mechanical engineering and machinery
url http://eprints.polsri.ac.id/361/1/COVER%282%29.pdf
http://eprints.polsri.ac.id/361/2/BAB1.pdf
http://eprints.polsri.ac.id/361/3/BAB2.pdf
http://eprints.polsri.ac.id/361/4/BAB3.pdf
http://eprints.polsri.ac.id/361/5/BAB4.pdf
http://eprints.polsri.ac.id/361/6/BAB5.pdf
http://eprints.polsri.ac.id/361/7/DAFTAR%20PUSTAKA%282%29.pdf
http://eprints.polsri.ac.id/361/8/lampiran.pdf
http://eprints.polsri.ac.id/361/
contents RIZKA INTAN YOLANDA 0611 3031 1452 MAJORING ELECTRICAL ENGINEERING Unbalance Load on the each phase of distribution lines substation in the I. 974 at PT. PLN (Persero) Rayon Sukaranmi to reduce neutral currents carried the burden of load balancing. And results of measurements and calculations show that the percentage of load imbalance each lines after the balancing the load is reduced. In the majors B from 72% to 6,67%, majoring C from 77.67% to 6.33%, majoring D from 72% to 6,67%,. Reduced the percentage of load imbalance with the current flowing in the neutral conductor is also reduced. In I. 974 substation measurement we cam see which phase that have unbalance load. Losses due to the current in the neutral conductor of the transformer in the LWBP is 6,285 kW and then balanced to LWBP is 0,079 kW. And WBP after balance is 26,091 kW and then balanced to LWBP is 0,221 kW. So, the bigger unbalance load happen, the losses cause by neutral conductor will be bigger. Key Words : Unbalance Load, Neutral Current, Losses
id IOS15200.361
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:27:40Z
last_indexed 2021-08-25T09:27:40Z
recordtype dc
_version_ 1709058411653496832
score 17.538404