ctrlnum 3253
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/3253/</relation><title>STUDI SISTEM SINKRONISASI GENERATOR SECARA OTOMATIS DI PT. PERTAMINA (PERSERO) RU III PLAJU</title><creator>SAPUTRA, EDWIN</creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>Synchronous generator (alternator) is an electric machine that converts mechanical energy into electrical energy. Operation of the generator required a generator of stability in order to become optimal performance. To serve the growing electrical load and at the time of maximum load, the alternator operation is usually carried out in parallel. The purpose of doing this study to determine the effect of synchronization on the parameters of electricity and the distribution in each generator working in parallel. Load used by consumers will affect the amount of active power and reactive power on each generator working in parallel. PT. Pertamina (Persero) RU III Plaju installed load of 50 MW. But the load used in PT. Peramina (Persero) RU III Plaju which is an average of 27.1 MW. PT. Pertamina (Persero) RU III Plaju process penyingkronan two generators used for the interconnection relay penyinkronannya Of the parallel work of two active power generator produces a daily average of around 26.82 MW. There is a loss of 1.65 MW of power under the comparison between the results of observations with calculations.</description><date>2016-07</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/1/file%20pelengkap.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/3253/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> SAPUTRA, EDWIN (2016) STUDI SISTEM SINKRONISASI GENERATOR SECARA OTOMATIS DI PT. PERTAMINA (PERSERO) RU III PLAJU. Other thesis, POLITEKNIK NEGERI SRIWIJAYA. </identifier><recordID>3253</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author SAPUTRA, EDWIN
title STUDI SISTEM SINKRONISASI GENERATOR SECARA OTOMATIS DI PT. PERTAMINA (PERSERO) RU III PLAJU
publishDate 2016
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/3253/1/file%20pelengkap.pdf
http://eprints.polsri.ac.id/3253/2/BAB%20I.pdf
http://eprints.polsri.ac.id/3253/3/BAB%20II.pdf
http://eprints.polsri.ac.id/3253/4/BAB%20III.pdf
http://eprints.polsri.ac.id/3253/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/3253/6/BAB%20V.pdf
http://eprints.polsri.ac.id/3253/7/DAFTAR%20PUSTAKA.pdf
http://eprints.polsri.ac.id/3253/
contents Synchronous generator (alternator) is an electric machine that converts mechanical energy into electrical energy. Operation of the generator required a generator of stability in order to become optimal performance. To serve the growing electrical load and at the time of maximum load, the alternator operation is usually carried out in parallel. The purpose of doing this study to determine the effect of synchronization on the parameters of electricity and the distribution in each generator working in parallel. Load used by consumers will affect the amount of active power and reactive power on each generator working in parallel. PT. Pertamina (Persero) RU III Plaju installed load of 50 MW. But the load used in PT. Peramina (Persero) RU III Plaju which is an average of 27.1 MW. PT. Pertamina (Persero) RU III Plaju process penyingkronan two generators used for the interconnection relay penyinkronannya Of the parallel work of two active power generator produces a daily average of around 26.82 MW. There is a loss of 1.65 MW of power under the comparison between the results of observations with calculations.
id IOS15200.3253
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:30:46Z
last_indexed 2021-08-25T09:30:46Z
recordtype dc
_version_ 1709058378740793344
score 17.538404