http://eprints.polsri.ac.id/1950/1/01.%20COVER.pdf http://eprints.polsri.ac.id/1950/2/02.%20BAB%20I.pdf http://eprints.polsri.ac.id/1950/3/03.%20BAB%20II.pdf http://eprints.polsri.ac.id/1950/4/04.%20BAB%20III.pdf http://eprints.polsri.ac.id/1950/5/05.%20BAB%20IV.pdf http://eprints.polsri.ac.id/1950/6/06.%20BAB%20V.pdf http://eprints.polsri.ac.id/1950/7/07.%20DAFTAR%20PUSTAKA.pdf http://eprints.polsri.ac.id/1950/ |
Daftar Isi:
- The purpose of this experiment is to find a formula protoyepe steam power plant to find a solution to the crisis of electricity in rural areas. Has conducted a study to determine heat loss at ukan incineration in furnaces and boiler superheater unit. The fuel used is diesel and LPG fuel with a mass of different - different. The results obtained from the calculation of the importance of the loss of heat radiation in the boiler furnace of 5.6%, 2.66% convection heat loss and heat conduction loss amounted to 5.73%, on the theory that it should heat loss should not be more than 1%. Heat loss occurring in the steam power plant prototype unit is still quite large when viewed from PLTGU PLN Keramasan sector with a heat loss in radias, conduction and convection. Heat loss can be mitigated in several ways one of them is a good insulator technique using cement or asbestos in accordance with the value of conductivity that dibutuhakan and can be determined from the results of the design calculations. Keywords: Electricity, heat loss, insulators.