fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/1732/</relation><title>ANALISA PENYETELAN RELAI GANGGUAN TANAH (GFR) PADA PENYULANG TRAFO 2 30 MVA 70/20 KV DI PT. PLN (PERSERO) GARDU INDUK BOOM BARU PALEMBANG</title><creator>Sari, Eka Aprianti Permata </creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>Medium voltage distribution network is a network of 20 kV primary distribution substations supplied from power plants or diesel using medium voltage cable line (SKTM) or medium voltage air line (SUTM). Short circuit often occurs at 20 kV network, interphase (3 phase or 2 phase), short circuit or phase to ground. If the protection is less good coordination, it can cause widespread blackout. So protective equipment used is over current relay (OCR) and ground fault relay (GFR) which will work to instruct the PMT to open so disturbed SKTM be separated from network. From the discussion known that 1 phase fault current to ground influenced by fault location and setting of ground fault relay is calculated in accordance with the conditions that have been set in the field.&#xD; Key Words : Protection, Fault Current, Ground Fault Relay</description><date>2015-10</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/1/COVER.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1732/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> Sari, Eka Aprianti Permata (2015) ANALISA PENYETELAN RELAI GANGGUAN TANAH (GFR) PADA PENYULANG TRAFO 2 30 MVA 70/20 KV DI PT. PLN (PERSERO) GARDU INDUK BOOM BARU PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>1732</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author Sari, Eka Aprianti Permata
title ANALISA PENYETELAN RELAI GANGGUAN TANAH (GFR) PADA PENYULANG TRAFO 2 30 MVA 70/20 KV DI PT. PLN (PERSERO) GARDU INDUK BOOM BARU PALEMBANG
publishDate 2015
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/1732/1/COVER.pdf
http://eprints.polsri.ac.id/1732/2/BAB%20I.pdf
http://eprints.polsri.ac.id/1732/3/BAB%20II.pdf
http://eprints.polsri.ac.id/1732/4/BAB%20III.pdf
http://eprints.polsri.ac.id/1732/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/1732/6/BAB%20V.pdf
http://eprints.polsri.ac.id/1732/7/DAFTAR%20PUSTAKA.pdf
http://eprints.polsri.ac.id/1732/
contents Medium voltage distribution network is a network of 20 kV primary distribution substations supplied from power plants or diesel using medium voltage cable line (SKTM) or medium voltage air line (SUTM). Short circuit often occurs at 20 kV network, interphase (3 phase or 2 phase), short circuit or phase to ground. If the protection is less good coordination, it can cause widespread blackout. So protective equipment used is over current relay (OCR) and ground fault relay (GFR) which will work to instruct the PMT to open so disturbed SKTM be separated from network. From the discussion known that 1 phase fault current to ground influenced by fault location and setting of ground fault relay is calculated in accordance with the conditions that have been set in the field. Key Words : Protection, Fault Current, Ground Fault Relay
id IOS15200.1732
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:29:11Z
last_indexed 2021-08-25T09:29:11Z
recordtype dc
_version_ 1709058394647691264
score 17.538404