fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/1719/</relation><title>PERHITUNGAN JATUH TEGANGAN PADA PENYULANG BELIMBING&#xD; YANG DISUPLAI DARI GARDU INDUK BOOM BARU DENGAN&#xD; BANTUAN SOFTWARE ETAP</title><creator>DHARMAWAN, MUHAMMAD RANDHIKA </creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>In electric power distribution always occur drop voltage and losses of electrical&#xD; power, it is caused by several factors such as, line resistance, line current, power&#xD; factor (Cos &#x3C6;), and the central load location which is far from the substation.&#xD; Thus, in the distribution of electricity through distribution line will having a drop&#xD; voltage along the line which reduces the supply of electrical energy distributed to&#xD; the central load location and make the electrical energy distributed to the&#xD; consumers reduced or in other word the electrical energy distributed to the&#xD; consumers is different from the energy that has been sent.&#xD; Drop voltage in distribution network can not be eliminated completely,&#xD; because of the equipments which is used in distribution system may not have an&#xD; efficiency 100 % but one thing that we should keep in mind is whether the drop&#xD; voltage is still in the tolerance limit or not.&#xD; This final report discusses the drop voltage calculations in the feeder by&#xD; using ETAP software. This final report was being done through a case study at&#xD; Boom Baru Substation especially in Belimbing Feeder.&#xD; The results of calculation and simulation that had been done by ETAP&#xD; 12.6 shows that the drop voltage which occurs is 0,84 on day peak burden and&#xD; 0,63 on night peak burden. The drop voltage that occured in Belimbing Feeder is&#xD; still in the limit allowed by PLN on SPLN 72:1987, amounting to 5 %.&#xD; Keywords : Drop voltage, distribution, ETAP</description><date>2015-10</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/1/Cover.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/6/Bab%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1719/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> DHARMAWAN, MUHAMMAD RANDHIKA (2015) PERHITUNGAN JATUH TEGANGAN PADA PENYULANG BELIMBING YANG DISUPLAI DARI GARDU INDUK BOOM BARU DENGAN BANTUAN SOFTWARE ETAP. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>1719</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author DHARMAWAN, MUHAMMAD RANDHIKA
title PERHITUNGAN JATUH TEGANGAN PADA PENYULANG BELIMBING YANG DISUPLAI DARI GARDU INDUK BOOM BARU DENGAN BANTUAN SOFTWARE ETAP
publishDate 2015
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/1719/1/Cover.pdf
http://eprints.polsri.ac.id/1719/2/BAB%20I.pdf
http://eprints.polsri.ac.id/1719/3/BAB%20II.pdf
http://eprints.polsri.ac.id/1719/4/BAB%20III.pdf
http://eprints.polsri.ac.id/1719/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/1719/6/Bab%20V.pdf
http://eprints.polsri.ac.id/1719/7/DAFTAR%20PUSTAKA.pdf
http://eprints.polsri.ac.id/1719/
contents In electric power distribution always occur drop voltage and losses of electrical power, it is caused by several factors such as, line resistance, line current, power factor (Cos φ), and the central load location which is far from the substation. Thus, in the distribution of electricity through distribution line will having a drop voltage along the line which reduces the supply of electrical energy distributed to the central load location and make the electrical energy distributed to the consumers reduced or in other word the electrical energy distributed to the consumers is different from the energy that has been sent. Drop voltage in distribution network can not be eliminated completely, because of the equipments which is used in distribution system may not have an efficiency 100 % but one thing that we should keep in mind is whether the drop voltage is still in the tolerance limit or not. This final report discusses the drop voltage calculations in the feeder by using ETAP software. This final report was being done through a case study at Boom Baru Substation especially in Belimbing Feeder. The results of calculation and simulation that had been done by ETAP 12.6 shows that the drop voltage which occurs is 0,84 on day peak burden and 0,63 on night peak burden. The drop voltage that occured in Belimbing Feeder is still in the limit allowed by PLN on SPLN 72:1987, amounting to 5 %. Keywords : Drop voltage, distribution, ETAP
id IOS15200.1719
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:29:11Z
last_indexed 2021-08-25T09:29:11Z
recordtype dc
_version_ 1709058394752548864
score 17.538404