ctrlnum 1715
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/1715/</relation><title>ANALISA KEDIP TEGANGAN AKIBAT PENGASUTAN MOTOR&#xD; PM-002 PADA SS 16 A 12 KV/6.6 KV DI PT PERTAMINA&#xD; (PERSERO) RU III PLAJU PALEMBANG</title><creator>PRABOWO, ADI </creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>Voltage Dips is a drop in the voltage value between 0.1 - 0.9 pu for a duration of 0.5 cycles - 1 minute. This voltage flicker occurs because of the starting of the motor which also increase the value of a current of 5-7 times the nominal current value. The motors are in asut in this case is the motor PM-002 is a motor with high voltage reaches 6.6 kV that are on line at SS 16 A high voltage power distribution network and the need for calculation of voltage flicker occurs. both large current calculation and calculation of the value of the pulsating voltage in volts and in the unit &#x201C;pu&#x201D; (per unit) which is adapted to the conditions that cause the motor start voltage flicker. On the results of the calculation of the value of the starting current, the voltage on the big blink SS 16 A 6.6 kV networks each - each are as follows: 87.60 A for the value of the starting current, 0.87 pu or 5807.9 Volt for great value voltage flicker. The duration of the voltage flicker was analyzed for 6 seconds it means tergolomg in voltage flicker TEMPORARY (3 seconds - 1 minute).&#xD; Keywords: substation, High Voltage Motor, Wink Voltage</description><date>2015-10</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/1/Cover.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1715/7/Daftar%20Pustaka.pdf</identifier><identifier> PRABOWO, ADI (2015) ANALISA KEDIP TEGANGAN AKIBAT PENGASUTAN MOTOR PM-002 PADA SS 16 A 12 KV/6.6 KV DI PT PERTAMINA (PERSERO) RU III PLAJU PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>1715</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author PRABOWO, ADI
title ANALISA KEDIP TEGANGAN AKIBAT PENGASUTAN MOTOR PM-002 PADA SS 16 A 12 KV/6.6 KV DI PT PERTAMINA (PERSERO) RU III PLAJU PALEMBANG
publishDate 2015
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/1715/1/Cover.pdf
http://eprints.polsri.ac.id/1715/2/BAB%20I.pdf
http://eprints.polsri.ac.id/1715/3/BAB%20II.pdf
http://eprints.polsri.ac.id/1715/4/BAB%20III.pdf
http://eprints.polsri.ac.id/1715/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/1715/6/BAB%20V.pdf
http://eprints.polsri.ac.id/1715/7/Daftar%20Pustaka.pdf
http://eprints.polsri.ac.id/1715/
contents Voltage Dips is a drop in the voltage value between 0.1 - 0.9 pu for a duration of 0.5 cycles - 1 minute. This voltage flicker occurs because of the starting of the motor which also increase the value of a current of 5-7 times the nominal current value. The motors are in asut in this case is the motor PM-002 is a motor with high voltage reaches 6.6 kV that are on line at SS 16 A high voltage power distribution network and the need for calculation of voltage flicker occurs. both large current calculation and calculation of the value of the pulsating voltage in volts and in the unit “pu” (per unit) which is adapted to the conditions that cause the motor start voltage flicker. On the results of the calculation of the value of the starting current, the voltage on the big blink SS 16 A 6.6 kV networks each - each are as follows: 87.60 A for the value of the starting current, 0.87 pu or 5807.9 Volt for great value voltage flicker. The duration of the voltage flicker was analyzed for 6 seconds it means tergolomg in voltage flicker TEMPORARY (3 seconds - 1 minute). Keywords: substation, High Voltage Motor, Wink Voltage
id IOS15200.1715
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:29:11Z
last_indexed 2021-08-25T09:29:11Z
recordtype dc
_version_ 1709058394784006144
score 17.538404