ANALISA PERBAIKAN SUSUT TEGANGAN DENGAN CARA PEMECAHAN BEBAN DI PT. PLN (PERSERO) RAYON SEKAYU PENYULANG BURGO GI BETUNG BERBASIS ETAP
Main Author: | RINELDY, REDHO AKBAR |
---|---|
Format: | Thesis NonPeerReviewed Book |
Bahasa: | eng |
Terbitan: |
, 2015
|
Subjects: | |
Online Access: |
http://eprints.polsri.ac.id/1709/1/Cover.pdf http://eprints.polsri.ac.id/1709/2/BAB%20I.pdf http://eprints.polsri.ac.id/1709/3/BAB%20II.pdf http://eprints.polsri.ac.id/1709/4/BAB%20III.pdf http://eprints.polsri.ac.id/1709/5/BAB%20IV.pdf http://eprints.polsri.ac.id/1709/6/BAB%20V.pdf http://eprints.polsri.ac.id/1709/7/DAFTAR%20PUSTAKA.pdf http://eprints.polsri.ac.id/1709/ |
ctrlnum |
1709 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/1709/</relation><title>ANALISA PERBAIKAN SUSUT TEGANGAN DENGAN CARA
PEMECAHAN BEBAN DI PT. PLN (PERSERO)
RAYON SEKAYU PENYULANG BURGO
GI BETUNG BERBASIS ETAP</title><creator>RINELDY, REDHO AKBAR </creator><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>The problem faced by the PT. PLN (Persero) as the only one sole
provider of electric energy is how to provide quality electricity services,
reliable, continuous, and has high efficiency. To meet those parameters, will
be solving the burden on Burgo Fedeer. In addition to reducing the voltage
losses in the network and to improve system reliability at the network, bypass
load carried on the burgo fedeer. This is done bypass load put on the pure
SUTM from outgoing burgo to incoming GH Babat as far as 33 km using 150
mm2 conductor A3CS. By using ETAP Sotware 12.6, simulating the bypass
load is done by drawing a single line diagram burgo feeder and integrate field
data into ETAP software. Burgo feeder network analysis results before bypass
loads using ETAP software acquired 12.6 voltage at the Air Balui load value
of 5,833 kV. Meanwhile, after bypass load increases the voltage values
obtained on Air Balui load of 7,541 kV. Based on these results, it can be seen
that the bypass load on the burgo feeder potentially reducing the voltage losses
in the network.</description><date>2015-10</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/1/Cover.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1709/7/DAFTAR%20PUSTAKA.pdf</identifier><identifier> RINELDY, REDHO AKBAR (2015) ANALISA PERBAIKAN SUSUT TEGANGAN DENGAN CARA PEMECAHAN BEBAN DI PT. PLN (PERSERO) RAYON SEKAYU PENYULANG BURGO GI BETUNG BERBASIS ETAP. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>1709</recordID></dc>
|
language |
eng |
format |
Thesis:Thesis Thesis PeerReview:NonPeerReviewed PeerReview Book:Book Book |
author |
RINELDY, REDHO AKBAR |
title |
ANALISA PERBAIKAN SUSUT TEGANGAN DENGAN CARA
PEMECAHAN BEBAN DI PT. PLN (PERSERO)
RAYON SEKAYU PENYULANG BURGO
GI BETUNG BERBASIS ETAP |
publishDate |
2015 |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
url |
http://eprints.polsri.ac.id/1709/1/Cover.pdf http://eprints.polsri.ac.id/1709/2/BAB%20I.pdf http://eprints.polsri.ac.id/1709/3/BAB%20II.pdf http://eprints.polsri.ac.id/1709/4/BAB%20III.pdf http://eprints.polsri.ac.id/1709/5/BAB%20IV.pdf http://eprints.polsri.ac.id/1709/6/BAB%20V.pdf http://eprints.polsri.ac.id/1709/7/DAFTAR%20PUSTAKA.pdf http://eprints.polsri.ac.id/1709/ |
contents |
The problem faced by the PT. PLN (Persero) as the only one sole
provider of electric energy is how to provide quality electricity services,
reliable, continuous, and has high efficiency. To meet those parameters, will
be solving the burden on Burgo Fedeer. In addition to reducing the voltage
losses in the network and to improve system reliability at the network, bypass
load carried on the burgo fedeer. This is done bypass load put on the pure
SUTM from outgoing burgo to incoming GH Babat as far as 33 km using 150
mm2 conductor A3CS. By using ETAP Sotware 12.6, simulating the bypass
load is done by drawing a single line diagram burgo feeder and integrate field
data into ETAP software. Burgo feeder network analysis results before bypass
loads using ETAP software acquired 12.6 voltage at the Air Balui load value
of 5,833 kV. Meanwhile, after bypass load increases the voltage values
obtained on Air Balui load of 7,541 kV. Based on these results, it can be seen
that the bypass load on the burgo feeder potentially reducing the voltage losses
in the network. |
id |
IOS15200.1709 |
institution |
Politeknik Negeri Sriwijaya |
institution_id |
186 |
institution_type |
library:university library |
library |
Perpustakaan Politeknik Negeri Sriwijaya |
library_id |
333 |
collection |
Perpustakaan Politeknik Negeri Sriwijaya |
repository_id |
15200 |
city |
KOTA PALEMBANG |
province |
SUMATERA SELATAN |
repoId |
IOS15200 |
first_indexed |
2021-08-25T09:29:05Z |
last_indexed |
2021-08-25T09:29:05Z |
recordtype |
dc |
_version_ |
1709058394820706304 |
score |
17.538404 |