ctrlnum 1677
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><relation>http://eprints.polsri.ac.id/1677/</relation><title>ANALISA EFISIENSI JARINGAN PADA SISTEM DISTRIBUSI&#xD; PRIMER 20 KV DI GARDU INDUK TALANG KELAPA&#xD; PT. PLN (PERSERO) TRAGI BORANG</title><creator>NUGRAHA, M. SINGGIH </creator><subject>TJ Mechanical engineering and machinery</subject><subject>TK Electrical engineering. Electronics Nuclear engineering</subject><description>Analysis of the efficiency of the distribution of electrical power distribution network is done in order to determine what percentage of the distribution of electrical power to the consumer. In the system of distribution of electricity from the power plant to be accepted by consumers would have suffered losses in voltage and power loss. The cause of the loss of voltage and power losses are partly due to the length of the electrical energy distribution system itself, the size of the diameter of the wire conductor is used, the type or types of wires used and the size of the resistivity of the conductive wire. When the distribution of electrical power system already contained a lot of voltage drop and power losses, so the efficiency of the distribution network is not 100% pure distributed. This final report investigates the magnitude of voltage drop, power losses and efficiency of power distribution networks. The calculation is performed through a case study on 20 kV of primary electrical power distribution network in some feeders at PT.PLN (Persero) Talang Kelapa substation. The calculations show the largest of voltage drop produce by Sadewa feeder by 20,27% with the highest active power losses at 76,2342 kW, thus cause the efficiency of the distribution become low by 94,2381%&#xD; Keywords: distribution system, voltage drop, power losses, efficiency</description><date>2015-10</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/1/Cover.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/2/BAB%20I.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/3/BAB%20II.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/4/BAB%20III.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/5/BAB%20IV.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/6/BAB%20V.pdf</identifier><type>Book:Book</type><language>eng</language><identifier>http://eprints.polsri.ac.id/1677/7/Daftar%20Pustaka.pdf</identifier><identifier> NUGRAHA, M. SINGGIH (2015) ANALISA EFISIENSI JARINGAN PADA SISTEM DISTRIBUSI PRIMER 20 KV DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO) TRAGI BORANG. Other thesis, Politeknik Negeri Sriwijaya. </identifier><recordID>1677</recordID></dc>
language eng
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
Book:Book
Book
author NUGRAHA, M. SINGGIH
title ANALISA EFISIENSI JARINGAN PADA SISTEM DISTRIBUSI PRIMER 20 KV DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO) TRAGI BORANG
publishDate 2015
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.polsri.ac.id/1677/1/Cover.pdf
http://eprints.polsri.ac.id/1677/2/BAB%20I.pdf
http://eprints.polsri.ac.id/1677/3/BAB%20II.pdf
http://eprints.polsri.ac.id/1677/4/BAB%20III.pdf
http://eprints.polsri.ac.id/1677/5/BAB%20IV.pdf
http://eprints.polsri.ac.id/1677/6/BAB%20V.pdf
http://eprints.polsri.ac.id/1677/7/Daftar%20Pustaka.pdf
http://eprints.polsri.ac.id/1677/
contents Analysis of the efficiency of the distribution of electrical power distribution network is done in order to determine what percentage of the distribution of electrical power to the consumer. In the system of distribution of electricity from the power plant to be accepted by consumers would have suffered losses in voltage and power loss. The cause of the loss of voltage and power losses are partly due to the length of the electrical energy distribution system itself, the size of the diameter of the wire conductor is used, the type or types of wires used and the size of the resistivity of the conductive wire. When the distribution of electrical power system already contained a lot of voltage drop and power losses, so the efficiency of the distribution network is not 100% pure distributed. This final report investigates the magnitude of voltage drop, power losses and efficiency of power distribution networks. The calculation is performed through a case study on 20 kV of primary electrical power distribution network in some feeders at PT.PLN (Persero) Talang Kelapa substation. The calculations show the largest of voltage drop produce by Sadewa feeder by 20,27% with the highest active power losses at 76,2342 kW, thus cause the efficiency of the distribution become low by 94,2381% Keywords: distribution system, voltage drop, power losses, efficiency
id IOS15200.1677
institution Politeknik Negeri Sriwijaya
institution_id 186
institution_type library:university
library
library Perpustakaan Politeknik Negeri Sriwijaya
library_id 333
collection Perpustakaan Politeknik Negeri Sriwijaya
repository_id 15200
city KOTA PALEMBANG
province SUMATERA SELATAN
repoId IOS15200
first_indexed 2021-08-25T09:29:05Z
last_indexed 2021-08-25T09:29:05Z
recordtype dc
_version_ 1709058395327168512
score 17.538404